Investigation of appropriate pre-analytical procedure for circulating free DNA from liquid biopsy.

Sato A, Nakashima C, Abe T, Kato J, Hirai M, Nakamura T, Komiya K, Kimura S, Sueoka E, Sueoka-Aragane N

Publication: Oncotarget (2018) • Vol 9 • Page 31904-31914PMID: 30159131View on PubMed

Purpose

This paper investigated the effects of precentrifugation storage of blood in K2EDTA, sodium citrate, Streck BCT, and PAXgene tubes on cell-free DNA (cfDNA) yields and fragment size. The effects of delayed processing of sodium citrate tubes, long-term frozen storage of cfDNA or plasma, and cfDNA extraction method on EGFR mutation quantification were also examined.

Conclusion

cfDNA concentrations and concentration of large DNA fragments increased in sodium citrate and K2EDTA plasma obtained by either centrifugation protocol with pre-centrifugation storage of blood at 4˚C and room temperature. The increases in cfDNA yield were only significant for sodium citrate plasma after 72 h at room temperature for 72 h or 4˚C for 1 week and in K2EDTA plasma after 72 h at either temperature, regardless of centrifugation protocol used. Importantly, sodium citrate plasma obtained after 72 h at 4˚C had comparable cfDNA levels and fragment size distribution to plasma from specimens stored for 72 h pre-centrifugation at room temperature in Streck BCT or PAXgene tubes.

The area under mutation peak for L858R was lower when blood was stored for 72 h preprocessing in sodium citrate tubes at room temperature than when blood was processed immediately or stored at 4˚C for 72 h. The area under mutation peak decreased when cfDNA was stored for 7 years compared to initial levels but the magnitude of the decrease was weakly correlated with mutation frequency. The magnitude of the decrease over the 7 years of storage was even larger when plasma was stored instead of extracted cfDNA. Importantly, the decrease was smaller when extraction was with cellulose magnetic beads than spin columns.

Studies (4)

Purpose

This study compared the effects of precentrifugation storage at room temperature and 4˚C on cfDNA yield and fragment size in K2EDTA and sodium citrate plasma. A total of 32 mL of blood was collected from each of ten healthy volunteers and divided among eight sodium citrate tubes and eight K2EDTA tubes. Blood was stored at room temperature for 0, 4, 24, and 72 h and at 4˚C for 4 h, 24 h, 72 h, and 1 week before plasma isolation. Plasma was obtained by centrifugation at 3000 rpm for 20 min. To investigate if these effects could be mitigated by centrifugation protocol, blood from five healthy volunteers was divided among four sodium citrate and four K2EDTA tubes. Sodium citrate plasma was obtained by centrifugation at 3000 x g for 20 min and K2EDTA plasma was obtained by centrifugation 1600 × g for 10 min followed by 16000 × g for 10 min. cfDNA was extracted from all plasma specimens using the Maxwell RSC kit and quantified by Quantus. cfDNA size was determined using a bioanalyzer.

Summary of Findings

The median cfDNA concentration in sodium citrate plasma increased progressively with pre-centrifugation storage of blood at 4˚C room temperature, but the increase was only significant when stored at room temperature for 72 h (P<0.001) or 4˚C for 1 week (P=0.019). Similarly, median cfDNA concentrations increased with increasing processing delay of K2EDTA plasma, but the changes were only significant when stored for 72 h or 1 week at 4˚C (P=0.021 and P<0.001, respectively) or for 72 h at room temperature (P<0.001). While a single 170 bp peak was observed in sodium citrate plasma from blood stored at 4˚C for up to 72 h, peaks of larger DNA (1-9 kb) were observed when blood was stored in either tube type at room temperature and when EDTA plasma was stored for 72 h or more at 4˚C. The concentration of DNA fragments of 1000-9000 bp in K2EDTA plasma was significantly higher when blood was stored at 4˚C for 72 h or longer (P<0.001, both), but the concentration of fragments of 100-250 bp was unaffected. Plasma from blood stored in K2EDTA tubes for 72 h and centrifuged twice also had higher cfDNA concentrations and a higher concentration of large fragments (>1000 bp) than that processed immediately (P=0.043, both), but there was no change in the concentration of short fragments.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    DNAAutomated electrophoresis/Bioanalyzer
    DNAFluorometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnticoagulant
    Potassium EDTA
    Sodium citrate
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageStorage duration
    0 h
    24 h
    4 h
    72 h
    StorageStorage temperature
    4˚C
    Room temperature