Skip to main content

Formalin fixation increases deamination mutation signature but should not lead to false positive mutations in clinical practice.

Prentice LM, Miller RR, Knaggs J, Mazloomian A, Aguirre Hernandez R, Franchini P, Parsa K, Tessier-Cloutier B, Lapuk A, Huntsman D, Schaeffer DF, Sheffield BS

Publication: PLoS One (2018) • Vol 13 • Page e0196434PMID: 29698444View on PubMed

Purpose

This paper investigated the effects of fixation duration, block storage duration, extraction method and uracil-N-glycosylase (UNG) treatment on sequencing quality control metrics and deamination events in formalin-fixed paraffin-embedded (FFPE) specimens.

Conclusion

Raw read counts were unaffected by up to 48 h of formalin fixation and extraction method (Qiagen FFPE kit, Qiagen GeneRead Kit with UNG, and Qiagen GeneRead Kit withot UNG), but the percentage of mapped reads decreased and the number of deamination single nucleotide variants (SNVs) increased with progressive fixation or block storage. Treatment with UNG decreased the number of deamination SNVs detected in specimens fixed for 48 h or stored as FFPE blocks for 20 years. The highest false positive variant allele frequency (VAF) was found in an UNG-treated specimen (1.48%), however as it was only 1.48% the authors report it is below clinical thresholds.

Studies (3)

Purpose

This study investigated the effects of extraction method on sequencing quality control metrics and deamination events in twenty colorectal specimens. No details of specimen processing were included and the authors state fixation times were unknown. However, all specimens were collected between 2015 and 2016. DNA was extracted from FFPE specimens using (i) the Qiagen FFPE kit after deparaffinization with mineral oil, (ii) the Qiagen GeneRead Kit with UNG, and (iii) the Qiagen Gene-Read Kit without UNG. Adapters were added using the Nextera XT index kit and specimens were sequenced on a MiSeq. SNVs were identified using MutationSeq v4.3.8 software. Deamination counts (C>T, G>A) that occurred at any VAF were compared against those of all other substitutions.

Summary of Findings

Raw read counts and read quality were comparable among case-matched FFPE specimens processed using three different DNA extraction methods. After normalization to the UNG treated specimens, 0-111 deamination events were identified per sample, with no differences observed between specimens extracted using the Qiagen FFPE kit and the Qiagen GeneRead kit.

  • Biospecimens

    TissueColorectal
  • Preservation Types

    Formalin
  • Diagnoses

    NeoplasticCarcinoma
  • Platforms

    DNANext generation sequencing
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Analyte Extraction and PurificationAnalyte isolation method
    Qiagen FFPE kit using mineral oil for deparaffization
    Qiagen Gene-Read Kit without UNG
    Qiagen GeneRead Kit with UNG