Stability of Proteins in Dried Blood Spot Biobanks.

Björkesten J, Enroth S, Shen Q, Wik L, Hougaard DM, Cohen AS, Sörensen L, Giedraitis V, Ingelsson M, Larsson A, Kamali-Moghaddam M, Landegren U

Publication: Mol Cell Proteomics (2017) • Vol 16 • Page 1286-1296PMID: 28501802View on PubMed

Purpose

This paper compared protein levels in dried blood and plasma specimens to matched liquid specimens and investigated the effects of long-term storage of dried blood specimens (DBS) from infants at 4˚C or -24˚C and liquid blood from adult men at -70˚C. The effect of patient age and the use of plasma versus serum specimen on protein abundance was also investigated using liquid specimens from adult men stored at -70˚C.

Conclusion

Although lower than the correlations observed for technical replicates, correlation in protein levels were very strong for matched dried and liquid specimens from a single patient, regardless of whether whole blood or plasma was used. Once correction for multiple testing was employed, none of the 92 proteins assayed were affected by position within the DBS. Storage duration at 4 or -24˚C accounted for 37% of the variation in DBS protein levels, with increased storage generally leading to decreased protein levels. Of the 92 proteins assayed, 61 declined with storage of DBSs at 4˚C and 22 declined with storage at -24˚C.  Of the 22 proteins affected by frozen storage, 20 were also affected by refrigerated storage. Overall protein stability was higher for specimens stored at -24˚C than 4 ˚C.

Of the 92 proteins assayed in liquid specimens stored at -70˚C, 58 were significantly affected by donor age and 58 differed between serum and plasma. However, only 5 proteins (S100A4, TGFα, HGF, ADAM 8, and ANXA1) were shown to be affected by storage duration of liquid specimens at -70˚C after correction for multiple testing. Of these, S100A4, HGF, and ADAM8 were also significantly affected by storage of DBS at 4˚C but none were affected by storage at -24˚C. Importantly, only 3.9% of the variation observed in liquid specimens stored at -70˚C was explained by storage duration.

Studies (3)

Purpose

This study compared protein levels in matched dried blood and plasma specimens to matched liquid specimens from a single volunteer. Some of the EDTA blood was transferred to a new tube and stored at 4˚C while the remainder was centrifuged for 15 min at 2000 x g to obtain plasma. DBS and dried plasma specimens (DPSs) were prepared in duplicate by allowing a 25 µL droplet of EDTA blood or plasma on the tip of a pipette to absorb onto Whatman DMPK-C sample paper. DBSs and DPSs were left to dry for 3 h at room temperature. Disks were punched from each DBS and DPS using a 1.2 mm Uni-Core micropuncher. The abundance of 92 proteins in DBS, DPS, blood, and plasma were determined using multiplex proximity extension assays (PEA) which uses real-time PCR-based amplification of oligonucleotides conjugated to antibodies to quantify protein levels.

Summary of Findings

Background levels were higher in dried specimens than in matched liquid specimens, but protein levels were very strongly correlated for blood (ρ=0.967-0.972) and plasma (ρ=0.968) regardless of adjustments for the higher background. However, the correlations were higher between technical replicates (ρ=0.999 for wet blood, dried blood, and wet plasma and ρ=0.994 for dried plasma) and between specimens collected from the middle versus edge of the DBS (ρ= 0.992-0.998). Slightly higher levels (<15%, P<0.05) of 10 of the 92 proteins and lower levels of 1 of the 92 proteins were found in the edge compared to the middle of the DBS, but none of the differences remained significant after correcting for multiple testing. As expected, protein levels were only modestly correlated between blood and plasma for both wet (ρ=0.631-0.650) and dried (ρ=0.600-0.604) specimens, reflecting the inclusion of cellular proteins in whole blood.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    Other PreservativeNone (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    ProteinImmuno-PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBiospecimen heterogeneity
    Dried blood spot sub-sampling (exact positions not specified)
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Whole blood
    Biospecimen PreservationType of fixation/preservation
    Air-dried
    None (fresh)