Skip to main content

Effect of different pre-analytical conditions on plasma lactate concentration.

Rako I, Mlinaric A, Dozelencic M, Juros GF, Rogic D

Publication: Biochem Med (Zagreb) (2018) • Vol 28 • Page 020701PMID: 29666554View on PubMed

Purpose

This paper investigated the effects of tube type, pre-centrifugation storage temperature, and post-centrifugation storage tube on lactate levels and hemolysis index in plasma.

Conclusion

Lactate levels were comparable between NaF/K3EDTA and NaF/KOX tubes but increased in both tube types when analysis was delayed by 24 h. Heparin plasma had significantly higher lactate levels than NaFK3EDTA plasma. When not aliquoted before storage, lactate levels were considered clinically inaccurate in 14% of lithium heparin specimens, but were considered clinically accurate in all specimens when plasma was aliquoted before storage. Lactate levels were significantly lower and hemolysis index higher when blood specimens in NaF/K3EDTA tubes were transported on ice rather than at room temperature.

Studies (2)

Purpose

This study investigated the effects of tube type, pre-centrifugation storage temperature, and post-centrifugation storage on lactate levels and hemolysis index in plasma. Comparisons of NaF/K3EDTA and NaF/KOX tubes was performed using the blood from seven patients in the department of thoracic surgery and 13 volunteers. The effect of pre-centrifugation storage temperature was investigated by storing blood from 50 patients in NaF/K3EDTA at room temperature and in an ice bath until centrifugation (15 min after collection). Blood specimens were collected after an overnight fast with minimal stasis and, 15 min after collection, were centrifuged at 2000 x g for 10 min. Blood specimens were stored at room temperature until centrifugation unless otherwise specified. After centrifugation, lactate and the hemolysis index were measured within 1 h using a Cobas c501 analyzer. Specimens in NaF/K3EDTA and NaF/KOX were then refrigerated and analyzed again after 24 h.

Summary of Findings

While lactate levels were on average 0.25 mmol higher when analysis was delayed by 24 h (statistics not presented), lactate levels were not significantly different between NaF/K3EDTA and NaF/KOX tubes when analyzed immediately or after 24 h. Lactate levels were significantly lower (P<0.001) and hemolysis index higher (P<0.001) when blood specimens in NaF/K3EDTA tubes were transported on ice rather than at room temperature. However, transport on ice did not cause a proportional or constant error and there was no correlation between lactate levels and hemolysis index.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Small moleculeClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnticoagulant
    Sodium fluoride/EDTA
    Sodium fluoride/potassium oxalate
    Biospecimen AcquisitionType of collection container/solution
    NaF/K3EDTA
    NaF/KOX
    StorageSpecimen transport duration/condition
    On ice
    Room temperature
    StorageStorage duration
    0 h
    24 h