Skip to main content

Evaluation of pre-analytical factors affecting plasma DNA analysis.

Markus H, Contente-Cuomo T, Farooq M, Liang WS, Borad MJ, Sivakumar S, Gollins S, Tran NL, Dhruv HD, Berens ME, Bryce A, Sekulic A, Ribas A, Trent JM, LoRusso PM, Murtaza M

Publication: Sci Rep (2018) • Vol 8 • Page 7375PMID: 29743667View on PubMed

Purpose

This paper compared cell-free DNA (cfDNA) extraction methods, blood collection protocols (tube type and delays), and use of prospectively collected versus retrospectively collected specimens on cfDNA yield and the percentage of low molecular weight (LMW) DNA. The effect of collection protocol on global nucleotide mismatch rate (GMR) was also investigated.

Conclusion

Significant differences between extraction kits on cfDNA yield and fragment size were observed. The highest median yields and fraction of LMW DNA were obtained using the spin column-based QIAamp Circulating Nucleic Acid kit. Plasma from specimens collected in K2EDTA tubes and processed after 1 h and those collected in Streck cell-free DNA tubes and processed after 24 or 72 had similar cfDNA yield, mean genome equivalents LMW DNA, fraction of LMW DNA, and global nucleotide mismatch rate (GMR). LMW fractions were significantly lower in retrospectively-analyzed archival specimens than in plasma prospectively collected for cfDNA analysis.

Studies (3)

Purpose

This study compared results of using different cfDNA extraction kits on the cfDNA yield and fragment size using a commercially-available K2EDTA plasma pool purchased from Bioreclamation IVT. Plasma was thawed, aliquoted, and stored at -80˚C upon receipt.  cfDNA aliquots were centrifuged at 14,000 x g for 10 min and supernatants were used for DNA extraction with one of the seven kits. For each kit, 10 replicate extractions were performed following the manufacturer’s instructions. DNA was quantified by a droplet digital PCR assay that amplified five short amplicons with a mean size of 71 bp and four long amplicons with a mean size of 471 bp and determined genome equivalents by dividing by five and four, respectively. LMW DNA was quantified as the difference between the number of genome equivalents as determined by the short amplicons and the long amplicons.

Summary of Findings

Significant differences between extraction kits were observed for cfDNA yield (P=5.01 x 10-11) and fragment size (P=.1.16 x 10-11). The highest median yields and fraction of LMW DNA were obtained using the spin column-based QIAamp Circulating Nucleic Acid kit. Although the yield using the QIAamp CNA kit was not significantly different from that using the second best performing kit (the spin column-based Norgen Plasma/Serum Cell-Free Circulating DNA Purification Midi Kit), the yields with the Norgen kit were much more variable among replicates.  Use of the best performing magnetic bead-based kit (Life Technologies MagMAX Cell-free DNA Isolation kit) resulted in a significantly lower yield than the QIAamp kit (P=0.946 x 10-5) and the remaining spin column-based (Analytik Jena PME free-circulating DNA Extraction Kit) and three magnetic bead-based kits (Promega Maxwell RSC ccfDNA Plasma kit, NeoGeneStar Circulating Cell Free DNA kit, and Omega Bio-Tek Mag-Bind Circulating DNA) resulted in even lower yields. However, the LMW fraction was comparable between the QIAamp Circulating Nucleic Acid kit and the Life Technologies MagMAX Cell-free DNA Isolation kit (89% and 90%, respectively), but was higher (Norgen Plasma/Serum Cell-Free Circulating DNA Purification Midi Kit and Promega Maxwell RSC ccfDNA Plasma kit) or lower (Analytik Jena PME free-circulating DNA Extraction Kit, NeoGeneStar Circulating Cell Free DNA kit and Omega Bio-Tek Mag-Bind Circulating DNA) using the remaining kits.

  • Biospecimens

    FluidPlasma
  • Preservation Types

    Frozen
  • Diagnoses

    Not specified
  • Platforms

    DNADigital PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Analyte Extraction and PurificationAnalyte isolation method
    Analytik Jena PME free-circulating DNA Extraction Kit
    Life Technologies MagMAX Cell-free DNA Isolation kit
    NeoGeneStar Circulating Cell Free DNA kit
    Norgen Plasma/Serum Cell-Free Circulating DNA Purification Midi Kit
    Omega Bio-Tek Mag-Bind Circulating DNA
    Promega Maxwell RSC ccfDNA Plasma kit
    QIAamp Circulating Nucleic Acid kit