This paper compared DNA yield and short tandem repeat (STR) analysis results from skin surface specimens collected from fingertips and forearms using three different methods. The effects of patient gender were also examined.
Evaluation of Skin Surface as an Alternative Source of Reference DNA Samples: A Pilot Study.
Albujja MH, Bin Dukhyil AA, Chaudhary AR, Kassab AC, Refaat AM, Babu SR, Okla MK, Kumar S
Purpose
Conclusion
DNA yields differed significantly between collection methods and location (forearm versus fingertip) with the highest yields obtained from specimens collected using tape, followed by swabs moistened with ethanol, and the lowest from swabs moistened with salicylic acid. STR analysis revealed that 71.7% of specimens could be amplified and genotyped successfully, 16.7% showed partial profiles (<16 but more than 10 markers), and only 11.7% specimens resulted in partial profiles (1–9 markers) with higher percentages of STR allele calls observed for swabs moistened with ethanol, followed by tape, and then swabs moistened with salicylic acid.
Studies (1)
Purpose
This study compared DNA yield and STR analysis results from skin surface specimens collected from fingertips and forearms of males and females using three different methods. Skin samples from the forearm and fingertips were self-collected by 10 volunteers (6 males and 4 females, 21-59 years old) by gently placing 25-mm2 fingerprint tape on the skin and then removing it or by rolling cotton-tipped swabs moistened with 70% ethanol or 10% salicylic acid over the surface of the skin at a 10-15° angle while rotating along the longitudinal axis. All samples were stored at room temperature for a maximum of 8 days before DNA isolation using a phenol chloroform isoamyl alcohol extraction method. DNA was quantified by real-time RT-PCR using the Quantifiler Human DNA Quantification kit. STR amplification was performed using the AmpFlSTR Identifiler plus PCR Amplification kit and analyzed by capillary electrophoresis.
Summary of Findings
DNA yields differed significantly between collection methods and body locations (P=0.014) with the highest yields obtained from specimens collected using tape (0.489 ng/µL from fingertips and 0.550 ng/µL from forearms), followed by swabs moistened with ethanol (0.406 ng/µL from fingertips and 0.161 ng/µL from forearms), and the lowest from swabs moistened with salicylic acid (0.181 ng/µL from fingertips and 0.150 ng/µL from forearms). STR analysis revealed that 43/60 specimens (71.7%) could be amplified and genotyped successfully, 10 (16.7%) showed partial profiles (<16 but more than 10 markers), and only seven specimens (11.7%) resulted in partial profiles (1–9 markers). Higher percentages of allele calls were observed for swabs moistened with ethanol from fingertips and forearms (99.7 and 99.4%, respectively) followed by tape from fingertips and forearms (99.1 and 91.5%, respectively) and the lowest percentages from swabs moistened with salicylic acid for fingertips and forearms (61.9 and 86.6%, respectively). No gender-related differences were observed.
Biospecimens
CellSkinPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
RNAReal-time qRT-PCRDNACapillary electrophoresis-MSPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Biospecimen location FingertipForearmBiospecimen Acquisition Method of cell acquisition Fingertip TapeSwab moistened with 10% salicylic acidSwab moistened with 70% ethanol