This review on the effects of preanalytical variability on RNA profiling examined the impact of block age on RNA yield, purity, and hybridization success and investigated the effects of microarray analytical workflow on the RNA profile.
Standardising RNA profiling based biomarker application in cancer-The need for robust control of technical variables.
Stewart JP, Richman S, Maughan T, Lawler M, Dunne PD, Salto-Tellez M
Purpose
Conclusion
Tumor block age was not correlated with total RNA yield, purity (absorbance at 260/280 or 260/230), cRNA yield, or the 3’ to 5’ ratio of actin and specimens that were successful were not newer than those that failed. RNA profiles were strongly correlated when sequential sections were sent to different facilities that used different workflows before assay on Almac Xcel arrays.
Studies (1)
Purpose
This review on the effects preanalytical variability on RNA profiling examined the impact of block age on RNA yield, purity, and hybridization success and investigated the effects of microarray analytical workflow on the RNA profile. The effects of block age were investigated in a total of 38 colon carcinoma specimens collected and processed between 1995 and 2007 by the Stratification in COloRecTal cancer (S:CORT) consortium, but no further details of specimen processing were described. RNA was extracted using the Roche High Pure RNA Paraffin kit. RNA yield and quality were determined by spectrophotometry. Actin 3’ to 5’ ratio and the assay success were determined following hybridization to the Almac Xcel array. Sequential sections from 42 FFPE colorectal tumor blocks were sent to two different facilities for RNA profiling. After extraction using the Roche HighPure RNA Paraffin kit, one facility used the Affymetrix 3’IVT PLUS reagents and the other used the NuGEN Ovation FFPE WTA System and Encore Biotin Module, after which, both facilities hybridized to Almac Xcel arrays.
Summary of Findings
Tumor block age was not correlated with total RNA yield, purity (absorbance at 260/280 or 260/230), cRNA yield, or the 3’ to 5’ ratio of actin and specimens that were successful were not newer than those that failed. RNA profiles were strongly correlated when sequential sections were sent to different facilities that used different workflows before assay on Almac Xcel arrays (R=0.8293).
Biospecimens
TissueColorectalPreservation Types
FormalinDiagnoses
NeoplasticCarcinomaPlatforms
RNASpectrophotometryRNADNA microarrayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage duration Collected in 1995Collected in 1996Collected in 1997Collected in 1998Collected in 1999Collected in 2000Collected in 2001Collected in 2002Collected in 2003Collected in 2004Collected in 2005Collected in 2006Collected in 2007DNA microarray Specific Template modification Affymetrix 3’IVT PLUS reagentsNuGEN Ovation FFPE WTA System and Encore Biotin Module