This paper investigated the effects of formalin buffering, tissue type, and block storage on the ratio of long to short real-time PCR amplicons and investigated the effects of using sections of biopsy rather than resection specimens on the DNA yield.
Formalin-fixed paraffin-embedded sample conditions for deep next generation sequencing.
Nagahashi M, Shimada Y, Ichikawa H, Nakagawa S, Sato N, Kaneko K, Homma K, Kawasaki T, Kodama K, Lyle S, Takabe K, Wakai T
Purpose
Conclusion
The ratio of long (129 bp) to short (41 bp) amplicons in the KAPA assay (Q-ratio) was significantly higher in specimens fixed in buffered formalin than those fixed in unbuffered formalin and in gastric cancer specimens than colorectal cancer specimens, but was not significantly different between breast cancer specimens and the other specimens types. Q-ratios declined with block storage duration but remained in the acceptable range for NGS when GC specimens were stored for <7 years. In contrast, Q-scores declined more rapidly in breast cancer specimens fixed in unbuffered formalin and were not suitable for NGS after only 4 years of storage.
Sections of breast cancer resection specimens yielded more DNA than sections of breast cancer biopsies thus more sections of biopsies were required to obtain enough DNA for analysis.
Studies (2)
Purpose
This study investigated the effects of formalin buffering, tissue type, and block storage on the ratio of long to short real-time PCR amplicons. Thirty-five breast cancer, one hundred thirty-four colorectal cancer, and one hundred thirty-eight gastric cancer resection specimens were fixed in neutral-buffered formalin (NBF) or unbuffered formalin (breast cancer resection only) for 24 h and embedded in paraffin and stored for up to 7 years. DNA was extracted from 20 µm sections using the BiOstic FFPE Tissue DNA Isolation Kit. DNA quality was determined by the real-time PCR based KAPA Human Genomic DNA Quantification and QC Kit which uses the ratio of 129 to 41 bp amplicons. Specimens with a ratio of greater than 0.1 were considered to be acceptable for NGS.
Summary of Findings
The ratio of long (129 bp) to short (41 bp) amplicons in the KAPA assay (Q-ratio) was significantly higher in specimens fixed in buffered formalin than those fixed in unbuffered formalin (0.83 versus 0.43, P<0.01). The Q-ratio was also significantly higher for gastric cancer specimens than colorectal cancer specimens (0.81 versus 0.69, P<0.05), but was not significantly different between breast cancer specimens and the other specimen types. Q-ratios declined with block storage duration and significant declines were observed for colorectal cancer specimens stored for 5-6 years and gastric cancer specimens stored for 3-4 years. Despite the declines, Q-ratios remained in the acceptable range for NGS when gastric cancer specimens were stored for <7 years. In contrast, Q-scores declined more rapidly in breast cancer specimens fixed in unbuffered formalin and were not suitable for NGS after only 4 years of storage.
Biospecimens
TissueBreastTissueColorectalTissueStomachPreservation Types
FormalinOther PreservativeDiagnoses
NeoplasticCarcinomaPlatforms
DNAReal-time qPCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Biospecimen location BreastColorectalGastricBiospecimen Preservation Type of fixation/preservation Formalin (buffered)Formalin (unbuffered)Storage Storage duration 1-2 years2-3 years3-4 years4-5 years5-6 years6-7 years<1 year<2 years>7 years
Purpose
This study compared DNA yields from sections obtained from breast cancer resections with that from biopsy specimens. Thirty-five breast cancer resection specimens and twenty breast cancer biopsy specimens were fixed in NBF for 24 h and embedded in paraffin and stored for up to 7 years. DNA was extracted from 20 µm sections using the BiOstic FFPE Tissue DNA Isolation Kit. DNA was quantified using the high sensitivity Quant-iT dsDNA Assay Kit.
Summary of Findings
Sections of breast cancer resection specimens yielded more DNA than sections of breast cancer biopsies. While 90% of resection specimens required only two sections to obtain sufficient DNA for analysis, just 80-85% of biopsy specimens yielded sufficient DNA for analysis when four sections were used.
Biospecimens
TissueBreastPreservation Types
FormalinDiagnoses
NeoplasticCarcinomaPlatforms
DNAFluorometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Method of tissue acquisition BiopsySurgical resection