This paper compared pH and coagulation analysis in citrated plasma analyzed fresh, after storage at -20˚C, and after -20˚C storage followed by storage on dry ice with or without subsequent storage at -80˚C.
The effects of dry ice exposure on plasma pH and coagulation analyses.
Trondsetås L, Mikkelsen G, Lian IA
Purpose
Conclusion
Compared to freshly processed plasma, plasma stored at -20˚C had higher pH and percentage of Protein C and plasma subsequently stored on dry ice had lower pH, fibrinogen levels, percentage of Protein C, and percentage of Protein S and higher prothrombin time international normalized ratio (PT-INR) and activated partial thromboplastin time (APTT). Interestingly, subsequent storage of specimens at -80˚C after dry ice storage reversed the effects such that only the pH was significantly different from that in freshly processed specimens.
Studies (1)
Purpose
This study compared pH and coagulation analysis in citrated plasma analyzed fresh, after storage at -20˚C, and after -20˚C storage followed by storage on dry ice with or without subsequent storage at -80˚C. Venous blood from 30 healthy volunteer was collected into four sodium citrate tubes. Plasma was obtained by centrifugation at 2500 x g for 15 min at room temperature and transferred to polypropylene tubes. Specimens were then analyzed fresh, after 48 h at -20˚C, after storage for 24 h at -20˚C followed by storage on dry ice at room temperature for 24 h, or after storage for 24 h at -20˚C followed by storage on dry ice at room temperature for 24 h and then -80˚C for 24 h. Frozen specimens were thawed in a water bath at 37˚C for 10-15 min. Specimen pH, APTT, fibrinogen, antithrombin, Protein C, and Protein S were determined by an autoanalyzer.
Summary of Findings
Plasma stored at -20˚C for 48h had higher pH and percentage Protein S than freshly processed plasma (7.42 versus 7.16, respectively and 108.90% versus 104.65%, respectively P<0.05, both). Plasma transferred to dry ice after 24 h at -20˚C rather than processed fresh had lower pH (6.13 versus 7.16, P<0.05), fibrinogen levels (2.44 versus 2.76, P<0.05), percentage of Protein C (100% versus 111%, P<0.05), and percentage of Protein S (103.80% versus 104.6%, P<0.05) and higher PT-INR (103 versus 0.96, P<0.05) and APTT (44.85 versus 31.70, P<0.05). When plasma was transferred to -80˚C after dry ice storage, the pH, fibrinogen, percentage of Protein C, and percentage of Protein S increased and the PT-INR and APTT decreased such that the pH was higher than in fresh plasma, but all other variables were comparable to that in fresh plasma.
Biospecimens
FluidPlasmaPreservation Types
None (Fresh)FrozenDiagnoses
NormalPlatforms
ProteinHematology/ auto analyzerSmall moleculepHMorphologyHematology/ auto analyzerGlycoproteinHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Preservation Type of fixation/preservation FrozenNone (fresh)Storage Storage duration 0 h48 h72 hStorage Storage temperature -20˚C-20˚C and dry ice-20˚C, dry ice and then -80˚C