This paper compared erythrocyte, leukocyte, epithelial cell, crystal, cast, and yeast counts in 213 matched urine specimens transferred to vacuum and non-vacuum containers.
Comparison of vacuum and non-vacuum urine tubes for urinary sediment analysis.
Topcuoglu C, Sezer S, Kosem A, Ercan M, Turhan T
Purpose
Conclusion
Erythrocyte, leukocyte, epithelial cell, crystal, cast, and yeast groupings were concordant between the specimen in the vacuum and non-vacuum tube for at least 196 of the 213 specimens.
Studies (1)
Purpose
This study compared erythrocyte, leukocyte, epithelial cell, crystal, cast, and yeast counts in the sediments of 213 matched urine specimens transferred to vacuum and non-vacuum containers. Urine was collected in containers with aspiration tubes connected to vacuum tubes and transferred to BD Vacutainer Z Plus Urine Tube and non-vacuum tubes. Urine was centrifuged at 400g for 5 min. Within 1 h of collection, the urinary sediment was resuspended in urine and 20 fields were examined by one technician at low and high power using a light microscope. The number of each type of cells per specimen was used to classify them into groups: Group I (0-5 cells), Group II (6-10 cells), Group III (11-30 cells), or Group IV (>30 cells). Specimens were classified as positive or negative for crystals, casts, and yeast.
Summary of Findings
Grouping of specimens based on erythrocyte, leukocyte, and epithelial cell counts or the presence of crystal, casts, and yeast were very strongly correlated between urinary sediments from matched specimens in vacuum and non-vacuum tubes (P=1.000, P=0.997, P=0.994, P=0.945, P=0.815, P=1.00 respectively, all P<0.001). Of the 213 specimens, concordant grouping was observed for the two specimens based on erythrocyte, leukocyte, and epithelial cell counts in 208, 199, and 196 cases, respectively. Similarly, concordant grouping based on the presence or absence of crystals, casts, and yeast were found in 209, 202, and 213 of the 213 specimens, respectively.
Biospecimens
FluidUrinePreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Cell count/volumeLight microscopyPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution BD Vacutainer Z Plus Urine TubeBD non-vacuum tube