Skip to main content

The pre-analytical processing of blood samples for detecting biomarkers on protein microarrays.

Rosskopf S, Gyurján I, Soldo R, Luna-Coronell JA, Vierlinger K, Singer CF, Rappaport C, Pecha N, Weinhaeusel A

Publication: J Immunol Methods (2015) • Vol 418 • Page 39-51PMID: 25675867View on PubMed

Purpose

This paper compared the correlations in immunoreactivity and number of differential reactive antigens (DIRAGS) among specimens collected in different tube types, after different delays to centrifugation, and before or after immunoglobulin (Ig) G purification.

Conclusion

Correlations in immunoreactivity were very strong among serum specimens from different tube types or subjected to different processing delays and strongly correlated among plasma specimens from different tube types or subjected to different processing delays. While spectrophotometric measurement indicated specimens collected in density gradient tubes had 2-fold more IgG than the other specimen types, this was not confirmed by SDS-PAGE.

Although the correlations between technical replicates and between time-points were higher for serum and plasma than for IgG-purified specimens, more differential reactive antigens (DIRAGS) between specimens from different patients were also found when plasma or serum was used instead of IgG. The number of antigens with a correlation of >0.5 between specimen duplicates or dilutions was approximately 50% higher for purified IgG specimens than serum. Further, dilution of purified IgG specimens resulted in a linear decrease in the mean signal intensities and number of DIRAGS, but the same was not observed for serum.

Studies (1)

Purpose

This study compared the correlations in immunoreactivity and number of DIRAGS among specimens collected in serum tubes with or without separator gel and plasma tubes with or without a density gradient, after different delays to centrifugation, and before or after IgG purification. Blood was collected from four healthy females into serum tubes with separator, serum tubes without gel separator, EDTA plasma tubes, and EDTA plasma tubes with a PolymorphPrep density gradient and stored at room temperature for 1, 4, 24, and 48 h before centrifugation. Plasma and serum were stored at -80˚C. Antibody profiles were determined for plasma and serum before and after IgG purification using the Melon Gel IgG Purification Spin Plate Kit using custom protein microarrays. To determine linearity serum and IgG were diluted 1:30, 1:50, 1:100, and 1:200.

Summary of Findings

The immunoreactivity of specimens was very strongly correlated among serum tube types (0.92-0.94), strongly correlated between plasma tube types (r=0.84-0.87), and modestly to strongly correlated between serum and plasma tubes processed after 1 h (r=0.66-0.72). Immunoreactivity was also very strongly correlated between specimens subjected to a 1 and 48 h processing delay in serum tubes with (r=0.92-0.94) or without (r=0.94-0.96) a separator gel and strongly correlated between specimens subjected to a 1 and 48 h processing delay in EDTA tubes with (r=0.88-0.90) or without (r=0.86-0.87) a density gradient. Similarly, the correlation between replicate specimens (same patient, collection tube, and processing delay) was slightly higher for serum specimens than plasma specimens (r=0.95-0.98 versus r=0.93-0.95). Although by spectrophotometric measurement specimens collected in density gradient tubes had 2-fold more IgG than the other specimen types, all specimens yielded similar SDS-PAGE bands and the gel band intensity was decreased for specimens collected in EDTA density gradient tubes. The correlations between technical replicates and between time-points were higher for serum and plasma than for purified IgG (r=0.873-0.923 versus r=0.842-0.885). However, more DIRAGS between specimens from different patients were found when plasma or serum was used instead of IgG (mean 247 versus 94), when stored for 24 h versus 1 h in serum tubes without separator (101 versus 78 for serum and 48 versus 30 for IgG–purified from serum), or in plasma tubes with density gradient (81 versus 58 for plasma and 68 versus 56 for IgG–purified from plasma). The authors state that IgG purification reduces the unspecific binding such that a higher percentage of the DIRAGS found in purified specimens are identified in the unpurified and a lower percentage of DIRAGS found in unpurified specimens are found in IgG.  

Dilution of the purified IgG-specimen before microarray analysis resulted in a linear decrease in the mean signal intensities, but the same was not observed for serum. Further, the number of antigens with a correlation of >0.5 between specimen duplicates or dilutions was approximately 50% higher for purified IgG than serum. The mean fluorescent intensity was increased with increasing quantity of IgG but not for serum amounts of greater than 2 µg. While the number of DIRAGs reduced linearly and slowly with dilution of the IgG specimens, it decreased rapidly for serum specimens.

  • Biospecimens

    FluidBlood
    FluidPlasma
    FluidSerum
  • Preservation Types

    None (Fresh)Frozen
  • Diagnoses

    Normal
  • Platforms

    ProteinSpectrophotometry
    Protein1D/2D gels
    ProteinAntibody microarray
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionTime of biospecimen collection
    EDTA tube
    EDTA tube with density gradient
    Serum separator tube with gel
    Serum tube without gel
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageStorage duration
    1 h
    24 h
    4 h
    48 h
    Analyte Extraction and PurificationAnalyte purification
    IgG purified using the Melon Gel IgG Purification Spin Plate Kit
    Not purified
    Antibody microarray SpecificAntibody dilution/concentration
    1:100
    1:150
    1:200
    1:30
    1:50