Efficient Detection of BRAF Mutation in Plasma of Patients after Long-term Storage of Blood in Cell-Free DNA Blood Collection Tubes.

Denis MG, Knol AC, Théoleyre S, Vallée A, Dréno B

Publication: Clin Chem (2015) • Vol 61 • Page 886-8PMID: 25896990View on PubMed

Purpose

This paper investigated the effects of delayed centrifugation of blood, tube type, and shipping on the detection of B-Raf proto-oncogene, serine/threonine kinase (BRAF) mutations in plasma.

Conclusion

Storage of uncentrifuged blood in EDTA tubes resulted in a decrease in the percentage of mutated DNA, but storage in BCT tubes did not affect the quantification of mutated DNA in eight of ten patients. Further, the quantification cycle values were comparable between blood that was processed immediately and blood shipped in BCT tubes and processed 4-6 days after collection.

Studies (1)

Purpose

This study investigated the effects of delayed centrifugation of blood, tube type, and shipping on the detection of BRAF mutations in plasma. To investigate the effects of tube type, blood was drawn from ten melanoma patients with a known V600E or V600K BRAF mutation into K3EDTA and BCT tubes. Blood was stored at room temperature and aliquots were removed after 2 h, 4 days, 7 days, and 10 days. Plasma was obtained by centrifugation at 2000 x g for 10 min. To investigate the effect of shipping, blood was drawn from six patients into BCT tubes, an aliquot was removed and processed immediately, and the remainder of the specimen was sent by mail at ambient temperatures. Specimens were then processed 4-6 days after collection. DNA was extracted using the PureLink Virus Kit and mutations were detected using the Therascreen BRAF RGQ kit.

Summary of Findings

Plasma obtained from blood stored uncentrifuged in EDTA tubes at room temperature had a decrease in the control quantification cycle value and comparable mutation specific quantification cycle values. Consequently, the amount of normal DNA in plasma was 6-, 44-, and 110-fold higher when uncentrifuged blood was stored at room temperature in EDTA tubes for 4, 7, and 10 days, respectively than when blood was centrifuged after 2 h. In contrast, the quantification cycle value was not affected in 8 of 10 specimens when uncentrifuged blood was stored in BCT tubes at room temperature, but smaller increases in normal DNA were observed in the remaining two specimens when compared to those stored in EDTA tubes. The quantification cycle values were comparable between blood that was processed immediately and blood shipped in BCT tubes and processed 4-6 days after collection.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    Streck/BCTNone (Fresh)
  • Diagnoses

    NeoplasticMelanoma
  • Platforms

    DNAReal-time qPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    BCT tube
    EDTA tube
    Biospecimen PreservationType of fixation/preservation
    Blood collection tube additive
    EDTA
    StorageBetween site transportation method
    Mailed
    Not transported
    StorageTime at room temperature
    10 days
    2 h
    4 days
    7 days
    Real-time qPCR SpecificTargeted nucleic acid
    Mutated BRAF
    Wildtype BRAF