Skip to main content

Stability of serum, plasma and urine osmolality in different storage conditions: Relevance of temperature and centrifugation.

Sureda-Vives M, Morell-Garcia D, Rubio-Alaejos A, Valiña L, Robles J, Bauça JM

Publication: Clin Biochem (2017) • Vol 50 • Page 772-6PMID: 28372954View on PubMed

Purpose

This paper investigated the effects of pre- and post-centrifugation storage temperature and duration on the stability of osmolality of plasma, serum, and urine based on three sets of guidelines.

Conclusion

Osmolality of serum and plasma increased over the storage duration with larger changes observed when stored at room temperature than at 4˚C and osmolality increased when stored as uncentrifuged blood rather than plasma and during the first 6 days when stored as uncentrifuged blood instead of serum. Urine osmolality was stable for 14 days at -21˚C but increased with storage at 4˚C or room temperature. The stability thresholds were longer when using the SEQC-ML and Westgaard guidelines than the WHO recommendations for serum and room temperature stored urine but were shorter for refrigerated urine.

Studies (2)

Purpose

This study investigated the effects of pre- and post-centrifugation storage temperature and duration on the stability of osmolality of plasma and serum using three sets of guidelines. Blood from 50 fasting adults was collected by venipuncture into four SST-II or lithium-heparin tubes. Two tubes of blood were immediately aliquoted; stored at room temperature and 4˚C for 1, 2, 3, 4, 5, 6, 7, 10, 11, 12, and 14 days; and then centrifuged at 2000x g for 10 min before assay while the other two were stored for 30 min at room temperature, centrifuged at 2000x g for 10 min, and then stored at room temperature and 4˚C for 1, 2, 3, 4, 5, 6, 7, 10, 11, 12 and 14 days prior to analysis.

Summary of Findings

Osmolality of serum increased over the storage duration with larger changes observed when stored at room temperature than at 4˚C and during the first 6 days when stored uncentrifuged. Serum osmolality was affected by storage of uncentrifuged blood with a procoagulant for as little as 24 h at room temperature by SEQC-ML and Westgaard guidelines but was stable for 2 days at room temperature by the RCPA-QAP guidelines and more than 14 days at 4˚C by all three sets of guidelines. Osmolality of serum stored at room temperature after centrifugation was stable for 4 days (SEQC-ML and Westgaard guidelines) or 6 days (RCPA-QAP guidelines) and when stored at 4˚C for 8 days (all three sets of guidelines).

Osmolality of plasma increased over the storage duration with larger changes observed when stored at room temperature than at 4˚C and when stored uncentrifuged.  Plasma osmolality was stable when uncentrifuged lithium-heparin anticoagulated blood was stored at room temperature for 3 (Westgaard guidelines), 4 (SEQC-ML guidelines), or 5 days (RCPA-QAP guidelines) or stored at 4˚C more than 14 days by all three sets of guidelines. Further, osmolality of lithium-heparin plasma was stable when stored at room temperature for 2 (Westgaard guidelines), 3 (SEQC-ML guidelines), or 4 days (RCPA-QAP guidelines) but only for 1 (Westgaard guidelines) or 2 days (SEQC-ML and RCPA-QAP guidelines). 

  • Biospecimens

    FluidBlood
    FluidPlasma
    FluidSerum
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Electrolyte/MetalClinical chemistry/auto analyzer
    Small moleculeClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    Whole blood
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageStorage duration
    1 day
    10 days
    11 days
    12 days
    14 days
    2 days
    3 days
    4 days
    5 days
    6 days
    7 days
    StorageStorage temperature
    4˚C
    Room temperature