Skip to main content

Optimal Fixation Conditions and DNA Extraction Methods for MLPA Analysis on FFPE Tissue-Derived DNA.

Atanesyan L, Steenkamer MJ, Horstman A, Moelans CB, Schouten JP, Savola SP

Publication: Am J Clin Pathol (2017)PMID: 28122725View on PubMed

Purpose

This paper investigated how DNA copy number ratio may be affected by the formula of formalin used (buffered versus unbuffered formalin), the duration and temperature of fixation, and extraction method. 

Conclusion

All specimens fixed in 10% buffered formalin (pH 6.8) for 12-24 h at room temperature had copy number ratios within the normal range of  0.8 and 1.2; however, copy number ratios were outside of normal range for 2-4%  and 14-18% when specimens were fixed in buffered formalin at room temperature for 1 h and 48-60 h, respectfully. Similarly, 4-5% of probes fell outside of the normal range for copy number ratio when specimens were fixed in buffered formalin at 4˚C for 12-24 h, while 70-75% of probes were outside of the normal range when specimens were fixed in unbuffered formalin at room temperature for 12-24 h. An in-house extraction method generated the most reliable copy number ratios and in most cases resulted in the largest percentage of probes with normal copy number ratios in comparison to the other extraction methods assessed. When the in-house method was followed by column purification for DNA isolated from lung tissue, the percentage of probes within the normal range for copy number ratio increased from 30-40% to 80%.

Studies (2)

Purpose

This study investigated how DNA copy number ratios may be affected by the formula of formalin used (buffered versus unbuffered formalin) and the duration and temperature of fixation in formalin-fixed paraffin-embedded (FFPE) colon specimens. Three 4 mm thick sections of a healthy colon specimen were processed with a Leica TP1050 and fixed in 10% formalin for 1 h, 12-24 h or 48-60 h at room temperature; in 10% formalin for 12-24 h or 48-60 h at 4˚C; or in unbuffered formalin (pH 3.0) for 12-24 h at room temperature. DNA was extracted from three 10 µm thick sections of 1 cm2 paraffin blocks using an unspecified method. Multiple ligation-dependent probe amplification (MLPA) was conducted using two probes sets (consisting of 50 and 55 probes, respectively) and a standard MLPA one-tube protocol and commercially-obtained DNA from the blood of one male or female donor as a copy number reference.

Summary of Findings

Copy number ratios for all probes were within the normal range of 0.8 and 1.2 when specimens were fixed for 12-24 h at room temperature. The percentage of probes that fell outside of the normal range for copy number ratio was 2-4% when specimens were fixed in buffered formalin at room temperature for 1 h, and 14-18% when specimens were fixed for 48-60 h. Similarly, 4-5% of probes fell outside of the normal range for copy number ratio when specimens were fixed in buffered formalin at 4˚C for 12-24 h, while 70-75% of probes were outside of the normal range when specimens were fixed in unbuffered formalin at room temperature for 12-24 h.

  • Biospecimens

    TissueColorectal
  • Preservation Types

    Formalin
  • Diagnoses

    Normal
  • Platforms

    DNAPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationTemperature of fixation/preservation
    4˚C
    Room temperature
    Biospecimen PreservationTime in fixative
    1 h
    12-24 h
    48-60 h
    Biospecimen PreservationType of fixation/preservation
    Formalin (buffered)
    Formalin (unbuffered)