Skip to main content

First morning voids are more reliable than spot urine samples to assess microalbuminuria.

Witte EC, Lambers Heerspink HJ, de Zeeuw D, Bakker SJ, de Jong PE, Gansevoort R

Publication: J Am Soc Nephrol (2009) • Vol 20 • Page 436-43PMID: 19092125View on PubMed

Purpose

This paper investigated if first-morning or subsequently voided urine was representative of the measurement of albumin and the albumin-to-creatinine ratio (ACR) in 24 h urine.

Conclusion

The median urinary albumin concentration (UAC) and ACR in first-morning urine were significantly lower than in 24-h urine but the median UAC and ACR of subsequently collected spot urine were higher than in 24-h urine.  First-morning urine results were more strongly correlated with 24-h urine and were more likely to agree with those in 24 h urine than subsequently collected spot urine.

Studies (1)

Purpose

This study investigated if first-morning or subsequently voided urine was representative of the measurement of albumin and the ACR in 24 h urine. Patients were participants in the Prevention of Renal and Vascular End-stage disease (PREVEND) study and, if on hypertensive medicine, were on a stable dosage. At three times separated by 3 weeks, 241 participants collected a 24 h urine specimen (10 PM-10 PM), a first-morning mid-stream void following the 24 h collection, and a subsequent void at the clinic. Urine was refrigerated for 48 h or less before measurement of albumin and creatinine using a Behring BN II analyzer.

Summary of Findings

Although the median urinary albumin concentration (UAC) and ACR in first-morning urine were lower than in 24-h urine (6.1 mg/L versus 6.5 mg/L, P=0.013 and 5.7 versus 8.3, P<0.001, respectively), the median UAC and ACR of subsequently collected spot urine were higher than in 24-h urine (11.5 versus 6.5 mg/L, P<0.001 and 10.5 versus 8.3, P<0.001).  UAC and ACR were strongly correlated between 24-h urine and first-morning urine (r=0.85 and r=0.87, respectively) and spot urine specimens (r=0.71 and r=0.73, respectively). Importantly, use of first-morning void rather than subsequent spot urine resulted in a higher percentage of albumin measurements within 30% of that in the 24-h urine and a reduced bias. Similarly, the percentage of first-morning urine specimens considered to have microalbuminuria by UAC and ACR were not significantly different from that in 24 h urine, but the percentage of microalbuminuric specimens was significantly higher (25.4% based on UAC and 24.5% based on ACR, versus 10% in 24 h urine, P<0.001, both) when spot urine was used. Intraindividual variation was lowest in 24-h urine followed by first-morning urine and was lower for ACR than UAC but was not substantially impacted by patient gender. Using gender-specific cut-offs, microalbuminuria results agreed with those in 24-h urine in 81.8% of first-morning specimens and 72.1% of subsequent void specimens.

  • Biospecimens

    FluidUrine
  • Preservation Types

    Other Preservative
  • Diagnoses

    Not specified
  • Platforms

    Small moleculeClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of fluid acquisition
    Voided urine (24-h collection)
    Voided urine (spot collection)
    Biospecimen AcquisitionTime of biospecimen collection
    10 PM-10 PM
    First morning
    Subsequent void