Influence of biological variations and sample handling on measured microalbuminuria in diabetic patients.

Vermes I, Spooren PF

Publication: J Clin Lab Anal (1992) • Vol 6 • Page 368-74PMID: 1432362View on PubMed

Purpose

This paper investigated the effects of storage, pH, freeze-thaw cycling, and vortexing alone or in combination with centrifugation on levels of albumin in urine from diabetic patients. The authors also investigated the effects of analysis method and time of collection on the variability of urine albumin levels and the effects of glycation on analysis of albumin levels in plasma.

Conclusion

Albumin levels were unaffected by storage of urine at room temperature for up to seven days, at 4˚C for up to three weeks, or at -20˚C for up to 12 weeks if pH was unadjusted. Similarly, there was no effect of 7 days of storage at -20˚C when thawed daily and vortexed or vortexed and centrifuged before analysis. Although there was no effect of up to 4 weeks of storage at -20˚C on albumin levels when the urine pH was adjusted to 5, 6, 7, or 8, albumin levels in urine adjusted to a pH of 4 declined by 36% after one week and 43% after four weeks.  Albumin excretion from the same patients over three days showed up to 34% variability in spot urine levels, but only 14% in 24 h specimens and 19% in timed overnight urine. Sensitivity and intra- and interassay variability were comparable for all five albumin quantification methods. Levels of albumin in urine and untreated or glycated plasma were also comparable among the five methods. 

Studies (1)

Purpose

This study investigated the effects of storage temperature and duration, pH, freeze-thaw cycling, and vortexing alone or in combination with centrifugation on levels of albumin in urine from diabetic patients. The authors also investigated effects of analysis method and time of collection on the variability of urine albumin levels and glycation on analysis of albumin levels in plasma. To compare the effects of analysis method, timed overnight urine from 296 diabetic patients (Type I and Type II) was analyzed by each of the four methods.  Urine from 12 patients was stored at room temperature for 0, 1, 2, 3, and 7 days, at 4˚C for 0, 1, 2, and 3 days and 1, 2, and 3 weeks; and -20˚C for 0, 1, 2, 3, 4, 8, and 12 weeks. Specimens were vortexed and centrifuged (1500 x g for 10 min) before analysis.  To investigate the effects of urine pH on albumin stability, the pH of urine aliquots was adjusted to 4, 5, 6, 7, and 8 prior to storage at -20˚C for 0, 1, and 4 weeks. To investigate the effects of thawing, 12 urine aliquots stored at -20˚C for 0 and 7 days were thawed daily at room temperature, vortexed or vortexed and centrifuged, and then refrozen. To test the effects of glycation, fresh-frozen plasma was stored with glucose and sodium azide at room temperature for 11 days and dialyzed before analysis. Urine specimens were collected overnight (pooled), at first void, at second void, and during the remainder of the day (pooled) on three consecutive days from eight diabetic patients.

Summary of Findings

Albumin levels were unaffected by storage of urine at room temperature for up to seven days, at 4˚C for up to 3 weeks, or at -20˚C for up to 12 weeks if pH was unadjusted. Similarly, there was no effect of seven days of storage at -20˚C when thawed daily and vortexed or vortexed and centrifuged before analysis. Although there was no effect of up to four weeks of storage at -20˚C on albumin levels when the urine pH was adjusted to 5, 6, 7, or 8, albumin levels in urine adjusted to a pH of 4 declined by 36% after one week and 43% after four weeks. Albumin excretion from the same patients over three days showed up to 34% variability in spot urine levels but only 14% in 24 h specimens and 19% in timed overnight urine. Sensitivity and intra- and interassay variability were comparable for all five albumin quantification methods and levels of albumin in urine were very strongly correlated between the turbidimetric immunoassay on the Cobas Fara and the RIA (r=0.985), the turbidimetric immunoassay on the Hitachi 717 (r=0.994), or the Turbitimer (r=0.997) and the nephelometric immunoassay (r=0.904).  Similarly, albumin levels were comparable among the five methods in untreated or glycated fresh-frozen plasma. 

  • Biospecimens

    FluidUrine
    FluidPlasma
  • Preservation Types

    FrozenNone (Fresh)
  • Diagnoses

    Diabetes Type 1
    Diabetes Type 2
  • Platforms

    ProteinRadioimmunoassay
    ProteinImmunoturbidometric assay
    ProteinClinical chemistry/auto analyzer
    ProteinImmunoassay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of fluid acquisition
    Voided urine (24-h collection)
    Voided urine (spot collection)
    Biospecimen AcquisitionTime of biospecimen collection
    24 h (pooled)
    First void
    Overnight (pooled)
    Second void
    Biospecimen Aliquots and ComponentsBiospecimen components
    Glycated
    Untreated
    Biospecimen Aliquots and ComponentsBiospecimen mixing
    Not vortexed
    Vortexed
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifuged
    Not centrifuged
    Biospecimen Aliquots and ComponentspH
    4
    5
    6
    7
    8
    Biospecimen PreservationType of fixation/preservation
    Frozen
    None (fresh)
    Refrigeration
    StorageFreeze/thaw cycling
    0 cycles
    7 cycles
    StorageStorage duration
    0 days
    1 day
    1 week
    12 weeks
    2 days
    2 weeks
    3 days
    3 weeks
    4 weeks
    8 weeks
    StorageStorage temperature
    -20˚C
    4˚C
    Room temperature
    StorageTime at room temperature
    0 days
    1 day
    2 days
    3 days
    7 days