Skip to main content

Considerations when measuring urinary albumin: precision, substances that may interfere, and conditions for sample storage.

MacNeil ML, Mueller PW, Caudill SP, Steinberg KK

Publication: Clin Chem (1991) • Vol 37 • Page 2120-3PMID: 1764788View on PubMed

Purpose

This paper investigated the effects of storage temperature, centrifugation or filtration before or after storage, and vortexing before storage on levels of albumin in urine. The effect of analysis method on the coefficient of variation was also investigated.

Conclusion

The mean degradation of specimens stored at -20˚C was 0.0192 mg/L, but the mean loss was only 0.0068 mg/L for specimens stored at -70˚C. There was no effect of centrifugation, filtration, or vortexing before storage; or centrifugation or filtration after storage. The rate of albumin degradation was significantly different among individuals (P=0.0001), but effects of storage conditions on albumin degradation did not differ significantly among individuals. The between day coefficients of variance were lower for radioimmunosassay (RIA) than ELISA or immunoturbidimetric assay (IT).

Studies (1)

Purpose

This study investigated the effects of storage temperature, centrifugation or filtration before or after storage, and vortexing before storage on levels of albumin in urine. The effect of analysis method on the coefficient of variation was also investigated. Five urine pools from healthy patients were spiked with various concentrations of albumin and two additional urine pools were preserved with tween-20 and were stored at -20˚C and assayed 20 times using each method. To investigate the effects of storage, urine from 12 patients without kidney disease were stored at -20˚C and -70˚C for 5-160 days and centrifuged, filtered, or vortexed before assay. The effect of filtration or centrifugation before storage was also investigated. Albumin levels were quantified by RIA, ELISA, and immunoturbidimetric assay.

Summary of Findings

The mean degradation of specimens stored at -20˚C was 0.0192 mg/L (P=0.089) or 0.27% per day, but the mean loss was only 0.0068 mg/L for specimens stored at -70˚C. There was no effect of centrifugation, filtration, or vortexing before storage; or centrifugation or filtration after storage. The rate of albumin degradation was significantly different among individuals (P=0.0001), but effects of storage conditions on albumin degradation did not differ significantly difference among individuals. The between-day coefficients of variance were lower for RIA than ELISA or IT, regardless of preservation with Tween-20.

  • Biospecimens

    FluidUrine
  • Preservation Types

    None (Fresh)Other Preservative
  • Diagnoses

    Not specified
  • Platforms

    ProteinELISA
    ProteinImmunoturbidometric assay
    ProteinRadioimmunoassay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    Centrifuged
    Not centrifuged
    Biospecimen Aliquots and ComponentsFiltration
    Centrifuged after storage
    Centrifuged before storage
    Filtered after storage
    Filtered before storage
    Vortexed
    Biospecimen PreservationFixative additive/buffer
    None
    Tween20
    StorageStorage duration
    5-160 days
    StorageStorage temperature
    -20˚C
    -70˚C
    4˚C
    Radioimmunoassay SpecificTechnology platform
    ELISA
    Immunoturbidimetric assay