Skip to main content

Comparison of the B-D urine culture kit with a standard culture method and with the MS-2.

Hubbard WA, Shalis PJ, McClatchey KD

Publication: J Clin Microbiol (1983) • Vol 17 • Page 327-31PMID: 6339550View on PubMed

Purpose

This paper investigated the effects of storing urine at room temperature in BD tubes rather than refrigerating in the original collection container and of analysis method on urine culture results.

Conclusion

Storage of urine at room temperature in BD tubes resulted in a larger decrease in the number of positive cultures and positive MS-2 results than when refrigerated in the collection container. The decline in positivity was greater when analyzed by MS-2 rather than by culture. Importantly, storage in BD tubes resulted in a lag in logarithmic growth compared to refrigerated storage.

Studies (2)

Purpose

This study investigated the effects of storing urine at room temperature in BD tubes rather than refrigerating in the original collection container on urine culture results and MS-2 analysis in 100 urine specimens. Clean-voided midstream or catheterized urine specimens were collected from 100 randomly selected patients who were submitting urine for analysis. Half of each urine specimen was transferred into a BD urine transport tube, mixed, and stored at room temperature. The remainder of the urine specimen was stored at 8 ˚C ± 2. Urine specimens were mixed well and cultured after 0 and 24 h and examined after 24 and 48 h. Specimens were analyzed with the Abbott Laboratories MS-2 system at 0, 5, and 24 h. 

Summary of Findings

When cultured immediately, 33 cultures were negative, 20 cultures were contaminated, 16 cultures had <104 cfu/mL, 5 cultures had 104-105 cfu/mL, and 26 cultures had >105 cfu/mL, regardless of tube type. Importantly, negative specimens were negative using either the standard culture method or the MS-2 system and while there was variability in counts among specimens with <105 cfu/mL, all remained <105 cfu/mL by both MS-2 and culture. There was no effect of refrigerated storage for up to 24 h in specimens with >105 cfu/mL, but the counts declined below 105 cfu/mL in 15% of specimens when stored in BD tubes. The detection rates were comparable for refrigerated and BD urine when analyzed by MS-2, but 6 of 26 organisms identified by culture were not found by MS-2.

  • Biospecimens

    FluidUrine
  • Preservation Types

    Other PreservativeNone (Fresh)
  • Diagnoses

    Not specified
    Other diagnoses
  • Platforms

    Cell count/volumeMicrobiological assay
    Cell count/volumeLight scattering
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Boric acid
    Glycerol
    None (fresh)
    Refrigeration
    Sodium formate
    StorageStorage duration
    0 h
    24 h
    5 h
    StorageStorage temperature
    8˚C
    Room temperature