Skip to main content

Accuracy of clean-catch urine collection in infancy.

Ramage IJ, Chapman JP, Hollman AS, Elabassi M, McColl JH, Beattie TJ

Publication: J Pediatr (1999) • Vol 135 • Page 765-7PMID: 10586183View on PubMed

Purpose

This paper compared the culture results obtained in clean-catch urine (CCU) with those obtained using suprapubic aspiration (SPA) specimens from infants suspected of having a urinary tract infection (UTI) and investigated if ultrasound increased SPA success.

Conclusion

CCU had a sensitivity of 88.9%, a specificity of 95.0%, a false positive rate of 5%, and a false negative rate of 12% for results obtained by SPA. The two false negative specimens included one with insufficient growth to be considered positive and one with mixed growth. Use of ultrasound to ensure urine adequacy increased the likelihood of SPA success.

Studies (1)

Purpose

This study compared the culture results obtained in CCU with those obtained using SPA specimens from infants suspected of having a UTI and investigated if ultrasound increased the SPA success. Both SPA and CCU specimens were collected from 49 patients (57 paired specimens) within 48 h of each other without use of antibiotics prior to collection or in the intervening time. To collect the CCU, infants were held on the lap (cleaned first if soiled) with a sterile foil bowl appropriately placed. SPA was obtained after ultrasound to ensure adequate urine in 28 cases. The SPA specimen was collected first in 28 pairs with a mean time between SPA and clean-catch of 3.6 h. The SPA and CCU were collected simultaneously in 18 cases. Urine was inoculated onto dip-slides and cultured for at least 16 h before analysis. A positive culture was defined as more than 105 cfu/mL of a single organism in a CCU specimen or any growth in a SPA specimen.

Summary of Findings

CCU had a sensitivity of 88.9%, a specificity of 95.0%, a false positive rate of 5%, and a false negative rate of 12% for positive results obtained by SPA. The majority of paired positive specimens (14 of 16) grew Escherichia coli with Pseudomonas aeruginosa and Candida albicans each cultured in one pair. Of the two false negative specimens, one grew Escherichia coli in the SPA and 103 cfu/mL Escherichia coli in the CCU and the other grew Escherichia coli in the SPA and a mixed growth in the CCU. Performing ultrasound prior to SPA increased SPA success on the first attempt from 13 of 21 patients to 26 of 28 patients (62% to 93%, P=0.008).

  • Biospecimens

    FluidUrine
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Other diagnoses
  • Platforms

    Cell count/volumeMicrobiological assay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionNon-invasive procedure type
    None
    Ultrasound
    Biospecimen AcquisitionMethod of fluid acquisition
    Different urine collection procedures compared
    Needle
    Voided urine (24-h collection)