Skip to main content

Effect of perineal cleansing on contamination rate of mid-stream urine culture.

Blake DR, Doherty LF

Publication: J Pediatr Adolesc Gynecol (2006) • Vol 19 • Page 31-4PMID: 16472726View on PubMed

Purpose

This paper investigated the effects of perineal cleansing on bacterial contamination of urine specimens.

Conclusion

There was no significant difference in colony counts between specimens collected with or without perineal cleaning, and while pathogenic bacterial contamination was not found in specimens collected after perineal cleansing it was found in only a single specimen collected without perineal cleansing.

Studies (1)

Purpose

This study investigated the effects of perineal cleansing on bacterial contamination of urine specimens from 50 women without discomfort when urinating. Two sequential urine specimens were collected midstream without perineal cleansing from 25 women. A single midstream urine specimen was collected from an additional 25 women following perineal cleansing using a towelette. Specimens were transported to the laboratory by an unspecified method and cultured. Bacterial growth was classified as pathogenic or peritoneal flora contamination. Counts were classified as no growth, 0-9,999 colonies/mL, 10,000-99,999 colonies/mL, or 100,000 colonies/mL or more.

Summary of Findings

There was no significant difference in colony counts between specimens collected with or without perineal cleaning. Pathogenic bacterial contamination was not found in specimens collected after perineal cleansing and found in only a single specimen collected without perineal cleansing. The remainder of the bacteria present were attributed to perineal flora and predominantly (33 of 36) consisted of mixed gram positive cultures.

  • Biospecimens

    FluidUrine
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    Cell count/volumeMicrobiological assay
    Cell count/volumeLight microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of fluid acquisition
    Collection site preparation methods compared
    Different urine collection procedures compared
    Voided urine (spot collection)