A novel midstream urine-collection device reduces contamination rates in urine cultures amongst women.

Jackson SR, Dryden M, Gillett P, Kearney P, Weatherall R

Publication: BJU Int (2005) • Vol 96 • Page 360-4PMID: 16042730View on PubMed

Purpose

This paper investigated the effects on contamination of urine collected using a novel mid-stream urine collection device rather than traditional methods. The effects of patient posture, reason for testing, and locale of testing on the significance of the effects was also investigated.

Conclusion

Although collection device did not affect the percentage of patients diagnosed with urinary tract infection (UTI), the novel collection device resulted in lower contamination rates (mixed growth or heavy growth) and reduced the need for retesting. Clinic, patient posture, and reason for test had no effect on the significance of the differences between sampling methods.

Studies (1)

Purpose

This study investigated the effects on contamination of urine collected using a novel mid-stream urine collection device rather than traditional methods. The effects of patient posture, reason for testing, and locale of testing on the significance of the effects was also investigated. Women visiting antenatal clinics and general practice were randomly assigned for urine collection using the novel mid-stream urine collection device (1077 specimens) or collection of mid-stream urine using non-standardized conventional methods (1105 specimens) used in each clinic. Labial separation and cleansing were not advised for the novel device but not all clinics provided instruction.  Analyses were conducted using dipsticks and culture.

Summary of Findings

Diagnosis of UTI occurred in a comparable number of specimens obtained with each method, but use of the novel device resulted in fewer specimens being classified as mixed growth (9% versus 14%, P=0.001) and heavy growth (1.2% versus 3.0%, P=0.004) and more specimens classified as clinically insignificant growth (88% versus 82%, P=0.005). Further, retesting was necessary in significantly fewer specimens collected using the novel device than the conventional methods (11% versus 16%, P=0.002). The novel collection system also resulted in less spillage than conventional collection (27% versus 46%, P<0.001). Clinic, patient posture, and reason for test had no effect on the significance of the differences between sampling methods.

  • Biospecimens

    FluidUrine
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
    Pregnant
  • Platforms

    Cell count/volumeLight microscopy
    Cell count/volumeMicrobiological assay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionLocale of biospecimen collection
    Different antenatal clinics
    Different general practice clinics
    Biospecimen AcquisitionMethod of fluid acquisition
    Different urine collection procedures compared
    Voided urine (spot collection)
    Biospecimen AcquisitionPatient posture
    Hovering
    Sitting
    Standing
    Biospecimen AcquisitionType of collection container/solution
    Novel midstream urine collection device
    Traditional urine collection cup