Skip to main content

Stability of miRNA in human urine supports its biomarker potential.

Mall C, Rocke DM, Durbin-Johnson B, Weiss RH

Publication: Biomark Med (2013) • Vol 7 • Page 623-31PMID: 23905899View on PubMed

Purpose

This paper investigated the effects of centrifugation, storage at 4˚C or room temperature, freeze-thaw cycling, and treatment with trypsin on levels of microRNA-16 (miR-16) and microRNA-21 (miR-21) in spot urine from healthy volunteers.

Conclusion

Levels of miR-16 and miR-21 were much higher in the pellet of centrifuged urine than in the supernatant or in uncentrifuged urine. Levels of miR-16 and miR-21 decreased with each freeze-thaw cycle and during storage at room temperature or 4˚C. However, the ratio of miR-16 to miR-21 was constant over the five days of storage at either temperature. Treatment of urine from five patients with trypsin had no effect on the cycle threshold (CT) of miR-16 or miR-21 in urinary exosomes, indicating their stability is not dependent on association with exosome bound structures

Studies (1)

Purpose

This study investigated the effects of centrifugation, storage for up to five days at 4˚C or room temperature, up to 10 freeze-thaw cycles, and treatment with trypsin on levels of miR-16 and miR-21 in spot urine from eight healthy volunteers. Urine aliquots were stored at 4˚C and room temperature for up to five days or subjected to up to 10 freeze-thaw cycles from -80˚C to room temperature before centrifugation at 25,000 x g at 4˚C and extraction of RNA from the resulting pellet. To investigate the effect of centrifugation, urine from three patients was centrifuged at 25,000 x g at 4˚C for 15 min and RNA was extracted from the pellet and the supernatant and from uncentrifuged aliquots from the same void. RNA was extracted with the miRNeasy Mini Kit and quantified by real-time PCR. Urinary exosomes were isolated from the urine of five healthy individual by a differential centrifugation protocol, but details were not specified.

Summary of Findings

Levels of miR-16 and miR-21 were much higher (7-9 CT) in the pellet of centrifuged urine than in the supernatant (P<=0.0001 and P=0.0023) or in uncentrifuged urine (P<0.0095 and P=0.0017, respectively). Levels of miR-16 and miR-21 decreased 14% and 10% (respectively), with each freeze-thaw cycle such that only 23% of the miR-16 and 37% of miR-21 remained after 10 freeze-thaw cycles. Similarly, miR16 and miR-21 declined by 19% per day when urine was stored at room temperature and 16% and 11% (respectively) per day when urine was stored at 4˚C. Thus, 35% of miR-16 and miR-21 remained after five days at room temperature, but 42% of the miR-16 and 56% of the miR-21 remained after five days at 4˚C. Importantly, the ratio of miR-16 to miR-21 was constant over the five days of storage at either temperature. Treatment of urine from five patients with trypsin had no effect on the CT of miR-16 or miR-21 in urinary exosomes, indicating their stability is not dependent on association with exosome bound structures.

.

  • Biospecimens

    FluidUrine
  • Preservation Types

    FrozenNone (Fresh)
  • Diagnoses

    Normal
  • Platforms

    RNAReal-time qRT-PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifuged
    Not centrifuged
    Biospecimen PreservationType of fixation/preservation
    Frozen
    None (fresh)
    StorageFreeze/thaw cycling
    0 cycles
    1 cycle
    10 cycles
    2 cycles
    3 cycles
    4 cycles
    5 cycles
    6 cycles
    7 cycles
    8 cycles
    9 cycles
    StorageStorage duration
    0 h
    1 day
    1 h
    12 h
    2 days
    3 days
    3 h
    4 days
    5 days
    6 h
    StorageStorage temperature
    4˚C
    Room temperature
    Real-time qRT-PCR SpecificTargeted nucleic acid
    miR-16
    miR-21