Circulating tumor cells and sample size: the more, the better.

Lalmahomed ZS, Kraan J, Gratama JW, Mostert B, Sleijfer S, Verhoef C

Publication: J Clin Oncol (2010) • Vol 28 • Page e288-9; author reply e290PMID: 20439640View on PubMed

Purpose

This paper explored how the volume of peripheral blood used may influence the number of circulating tumor cells (CTCs) detected by the CellSearch method.

Conclusion

Analysis of 30 mL aliquots of peripheral blood by CellSearch yielded higher CTC counts as well as a higher percentage of patients with ≥1 CTCs per aliquot and ≥3 CTCs per aliquot than when 7.5 mL aliquots were analyzed by the same methods.

Studies (1)

Purpose

This study explored how the volume of peripheral blood used may influence the number of CTCs detected by the CellSearch method. Forty mL of peripheral arterial blood was collected in 10 mL CellSave tubes from 15 patients undergoing liver resection and/or open radio frequency ablation prior to surgery. Blood was pooled, stored at room temperature, and processed within 72 hours of collection. A 30 ml aliquot and a 7.5 ml aliquot was analyzed for each patient. Each 30 ml aliquot was subjected to a modified Ficoll density gradient separation, which resulted in a reduced volume of 7.5 mL of enriched blood to permit analysis by CellSearch.

Summary of Findings

The median number of CTCs recovered from peripheral blood was statistically higher for 30 mL aliquots than 7.5 mL aliquots (two CTCs versus one CTC, range 0-9 versus 0-4, P=.03) and the median paired difference between the two volumes was one (range of -1 to 7). Further, CTCs were detected in a higher percentage of patients when using blood enriched from a 30 mL aliquot compared to the 7.5 mL aliquot (≥1 CTC were detected in 87% versus 67% of patients and ≥3 CTCs detected in 47% compared to 13% of patients, respectively).

  • Biospecimens

    FluidBlood
  • Preservation Types

    Other Preservative
  • Diagnoses

    NeoplasticCarcinoma
  • Platforms

    Cell count/volumeLight microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsAliquot size/volume
    30 mL
    7.5 mL