This paper investigated the effects of using dried urine spots rather than urine and storage of dried urine spots on the measured levels of creatinine and hippuric acid using HPLC with a diode array detector (DAD).
Development, validation and clinical evaluation of a dried urine spot method for determination of hippuric acid and creatinine.
Antunes MV, Niederauer CG, Linden R
Purpose
Conclusion
When dried urine spots were used, the concentration of hippuric acid averageed 116% of that in urine and the concentration of creatinine averaged 89% of that in urine. There was no effect of storing dried urine spots for 11 days at 4, 25, or 40˚C on levels of creatinine or hippuric acid, regardless of initial concentration. Although the hippuric acid to creatinine ratio in dried urine spots averaged 116% of that in urine, the risk classification of toluene exposure based on the hippuric acid to creatinine ratios was in agreement between matched dried urine spots and urine for all 49 patients.
Studies (1)
Purpose
This study investigated the effects of using dried urine spots rather than urine and storage of dried urine spots on the measured levels of creatinine and hippuric acid using HPLC-DAD. Aliquots of urine containing 630 mg/L creatinine and 200 mg/hippuric acid or 1200 mg/L creatinine and 2700mg/L hippuric acid were spotted onto Whatman paper and allowed to dry at room temperature for 3 h. Dried urine specimens were stored in sealed bags at 4, 25, and 40˚C for 1, 4, 7, and 11 days. Levels of creatinine and hippuric acid were also determined in 49 patients exposed to toluene. Levels of creatinine and hippuric acid were measured by placing 5 mm punches of the dried urine spot in purified water and vortexing before HPLC-DAD analysis.
Summary of Findings
Urine volume was very strongly correlated to urine dried spot area (r=0.9981). When dried urine spots were used, the concentration of hippuric acid averaged 116% of that in urine and the concentration of creatinine averaged 89% of that in urine. There was no effect of storing dried urine spots for 11 days at 4, 25, or 40˚C on levels of creatinine or hippuric acid, regardless of initial concentration. Although the hippuric acid to creatinine ratio in dried urine spots averaged 116% of that in urine, the risk classification of toluene exposure based on the hippuric acid to creatinine ratios was in agreement between matched dried urine spots and urine for all 49 patients.
Biospecimens
FluidUrinePreservation Types
None (Fresh)Other PreservativeDiagnoses
Not specifiedOther diagnosesPlatforms
Small moleculeHPLCPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Biomarker level 1200 mg/L creatinine and 2700mg/L hippuric acid630 mg/L creatinine and 200 mg/hippuric acidBiospecimen Preservation Type of fixation/preservation Air-driedNone (fresh)Storage Storage duration 1 day11 days4 days7 daysStorage Storage temperature 25˚C40˚C4˚C