The effect of storage pH on the precipitation of proteins in deep frozen urine samples.

Townsend JC, Sadler WA, Shanks GM

Publication: Ann Clin Biochem (1987) • Vol 24 ( Pt 1) • Page 111-2PMID: 3827174View on PubMed

Purpose

This paper investigated the effects of urine pH, storage duration, and removal of particulates on the levels of albumin, β-2 microglobulin (B2M), and gamma globulin in urine.

Conclusion

Centrifugation to remove particulates prior to analysis of urine specimens with a pH of less than 5.5 resulted in lower measured levels of albumin, B2M, and gamma globulin, but no effect was observed when the pH was adjusted to 7.0 before storage. The effect of centrifugation on specimens was greater when the specimens were stored for six weeks than when stored for three weeks.

Studies (1)

Purpose

This study investigated the effects of urine pH, storage duration, and removal of particulates on the levels of albumin, B2M, and gamma globulin in urine. Urine was aliquoted and one aliquot was adjusted to pH 7.0 with NaOH while the other remained at pH 4.9-6.9. The aliquots were stored at -20˚C and levels of B2M and albumin were determined after three and six weeks (method of determination not specified) and levels of gamma globulin were determined by ELISA after six weeks. Specimens were either centrifuged at 1000 x g for 10 min (particulate removal) or vortexed (particulate retention) before analysis. 

Summary of Findings

Three specimens with a pH of less than 5.5 had lower levels of B2M, albumin, and gamma globulin when centrifuged before analysis than when vortexed. The magnitude of the decline in albumin and B2M was larger when the specimens had been stored for six weeks than for three weeks.  The authors report that when the pH of the urine was adjusted to 7.0 prior to storage, there was no difference in levels of B2M, albumin, or gamma-globulin, regardless of centrifugation. The authors also report there were differences in the urine deposits between pH-adjusted and not-adjusted specimens, but there were no similar consistent effects due to centrifugation.

  • Biospecimens

    FluidUrine
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    ProteinClinical chemistry/auto analyzer
    GlycoproteinELISA
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifuged
    Not centrifuged
    Biospecimen Aliquots and ComponentspH
    7
    Unadjusted
    StorageStorage duration
    3 weeks
    6 weeks