This review examined the variability of protein concentrations between first morning, second morning and other spot urine collections and 24 h collection.
Urine collection and processing for protein biomarker discovery and quantification.
Thomas CE, Sexton W, Benson K, Sutphen R, Koomen J
Purpose
Conclusion
The relative standard deviation was lowest for 24 h collections (39%), followed by first morning collections (41%), second morning specimens (54%), and spot collections (61%). The average protein concentrations were comparable between pooled 24 h collections, and the second morning urine and other spot collections,(26 mg/mL), but were slightly higher in first morning urine (34 mg/mL).
Studies (1)
Purpose
This study examined the variability of protein concentrations among first morning, second morning and other spot urine collections and 24 h collection. Urine was collected from a single subject (no specified diagnosis) over a period of ten days and the protein concentrations were measured in first morning collections, second collections, each spot collection, and a pooled 24 h collection.
Summary of Findings
The relative standard deviation was lowest for 24 h collections (39%), followed by first morning collections (41%), second morning specimens (54%) and other spot collections (61%). The average protein concentrations were comparable between pooled 24 h collections, second morning urine, and other spot collections(26 mg/mL), but were slightly higher in first morning urine (34 mg/mL).
Biospecimens
FluidUrinePreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
ProteinColorimetric assayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Method of fluid acquisition Voided urine (24-h collection)Voided urine (spot collection)Biospecimen Acquisition Time of biospecimen collection First morning urineSecond morning urine