Skip to main content

RNA extraction from healthy and failing human myocardium: a comparative evaluation.

Hong YH, Martin LA, Mulvaney JM, Burhans MS, Blaxall BC, Hinton RB

Publication: Biopreserv Biobank (2015) • Vol 13 • Page 123-30PMID: 25825942View on PubMed

Purpose

This paper investigated the effects of extraction method on the yield, purity, integrity, and expression levels of RNA in specimens from heart failure and healthy heart. 

Conclusion

Although the RNA yield and recovery of low molecular weight RNA was highest when extraction was with TRIzol, the RNeasy method yielded RNA with higher purity and integrity as determined by RNA quality index (RQI) and 28S/18S rRNA ratio. However, the effects of extraction method on RNA integrity were only significant in healthy specimens.  While cycle threshold (CT) values for the control gene (glyceraldehyde 3-phosphate dehydrogenase, GAPDH) were significantly lower when extraction was with TRIzol rather than RNeasy or the combined method, the CT values for b-myosin heavy chain (MHC7) and c-cardiac myosin binding protein-C (MYBPC-3) were lowest when extracted with the combined method. Importantly, while the method of extraction affected the CT values in different ways and the normalized expression levels were extraction method-dependent, similar results were observed using control or heart failure specimens.

Studies (1)

Purpose

This study investigated the effects of extraction method on the yield, purity, integrity, and expression levels of RNA in specimens from heart failure and healthy heart.  Specimens from the left ventricular apical free wall were obtained from five patients during LV assist placement and from five organ donors who died in motor vehicle accidents. Specimens obtained during surgery were placed in liquid nitrogen and stored for 8-9 years at -140˚C while those obtained from organ donors were transported on ice in histidine-tryptophan-ketoglutarate (HTK). All specimens were homogenized using a Precellys 24 homogenizer. Tissue was homogenized directly in Trizol or RNeasy buffer. The combined method started with a TRIzol extraction but the aqueous phase was loaded into the RNeasy QIAcube. RNA was stored at -80˚C. RNA was quantified by spectrophotometer and quality was assessed by Bioanalyzer.  Expression of MYBPC-3, MHC7, and GAPDH were determined by real-time PCR. 

Summary of Findings

The RNA yield from control and heart failure specimens was higher using the TRIzol than the RNeasy method (P=0.0003 and P=0.0004, respectively) or the combined method (P=0.0057 and P=0.0067, respectively); however, purity as determined by the ratio of OD260 to 280, was lower when extraction was with the TRIzol method rather than RNeasy (P=0.0015 and P=0.01, respectively) or the combined method (P=0.0018 and P=0.01, respectively). Further, the integrity of RNA extracted from control specimens was higher as determined by the 28S/18S ratio when extracted using RNeasy rather than TRIzol (P=0.033) or the combined method (P=0.0027) and resulted in higher RQI than the hybrid method (P=0.047). However, no significant differences in integrity by 28S/18S ratio or RQI were observed among the extraction methods in heart failure specimens and the TRIzol method resulted in better preservation of low molecular weight RNAs. CT values for GAPDH were significantly lower when extraction was with TRIzol than RNeasy (P<0.0001) or the combined method (P<0.001), but CT values for MHC7 were higher when extracted with the combined method compared to the TRIzol (P<0.0001) or RNeasy (P<0.001) methods and CT values for MYBPC-3 were higher when extraction was with the combined method rather than RNeasy (P<0.05). Importantly, while the method of extraction affected the CT values in different ways and the GAPDH normalized expression levels of MHC-7 and MYBPC-3 were extraction method-dependent, similar results were observed using control or heart failure specimens.

  • Biospecimens

    TissueHeart
  • Preservation Types

    Frozen
  • Diagnoses

    Cardiovascular Disease
    Autopsy
    Normal
  • Platforms

    RNAAutomated electrophoresis/Bioanalyzer
    RNASpectrophotometry
    RNAReal-time qRT-PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Heart failure
    Normal
    Analyte Extraction and PurificationAnalyte isolation method
    Combined TRIzol/RNeasy
    RNeasy
    TRIzol
    Real-time qRT-PCR SpecificTargeted nucleic acid
    GAPDH
    MHC7
    MYBPC-3