Skip to main content

Reliability of urinary albumin, total protein, and creatinine assays after prolonged storage: the Family Investigation of Nephropathy and Diabetes.

Parekh RS, Kao WH, Meoni LA, Ipp E, Kimmel PL, La Page J, Fondran C, Knowler WC, Klag MJ

Publication: Clin J Am Soc Nephrol (2007) • Vol 2 • Page 1156-62PMID: 17928473View on PubMed

Purpose

This paper compared urinary albumin, creatinine, and protein levels and albumin to creatinine ratio (UAC) in fresh and frozen specimens and investigated the effects of storage duration at -70˚C.

Conclusion

During storage at -70˚C there were significant declines in urinary albumin, total protein, and UAC but creatinine levels were unaffected.  The declines resulted in changes in classification for 5 of 209 specimens that were originally classified as normal, 9 of 75 originally classified as having microalbuminuria, and 0 of the 59 specimens initially classified as having overt albuminuria. The correlation between fresh and frozen specimens was 0.8 for urinary creatinine, 0.9 for urinary albumin, and 0.99 for UAC. Regression analysis revealed that for every 1 mg/ml increase in creatinine in the fresh specimens there was a 0.86 unit increase in albumin in the frozen specimens.

Studies (1)

Purpose

This study compared urinary albumin, creatinine, and protein levels and UAC in fresh and frozen specimens and investigated the effects of storage duration at -70˚C. Urine specimens were collected at eight different centers from 351 individuals with a family history of diabetic nephropathy, African Americans with nephropathy and their spouse or children, or Mexican-Americans with diabetes. Specimens were shipped overnight on ice before aliquoting and storage at -70˚C. Specimens from 21 individuals were also analyzed fresh.  

Summary of Findings

Over each 30-day period, urinary albumin levels declined by an average of 0.27% (P=0.009), total protein by an average of 0.17% (P=0.007), and UAC by an average of 0.33% (P<0.001). The percentage decline in protein, albumin, and UAC were comparable between patients with diabetes and those without. Creatinine measurements were not affected by storage duration at -70˚C Only 5 of 209 patients with normal urinary albumin levels were classified as having microalbuminuria after storage. Of the 75 specimens initially classified as having microalbuminuria, four were classified as having overt albuminuria and five as having normal UAC ratio. None of the 59 specimens classified as overt albuminuria were classified differently at reanalysis. Importantly, the authors state that all of the specimens that were reclassified after storage had initial albumin levels close to cut-off. The correlation between fresh and frozen specimens was 0.8 for urinary creatinine, 0.9 for urinary albumin, and 0.99 for UAC. Regression analysis revealed that for every 1 mg/ml increase in creatinine in the fresh specimens there was a 0.86 unit increase in albumin in the frozen specimens.

  • Biospecimens

    FluidUrine
  • Preservation Types

    Frozen
  • Diagnoses

    Diabetes Type 2
    Diabetes Type 1
    Normal
  • Platforms

    ProteinClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Diabetes
    Normal
    Biospecimen PreservationType of fixation/preservation
    Frozen
    None (fresh)
    StorageStorage duration
    0-30 months