Use of magnetic beads for plasma cell-free DNA extraction: toward automation of plasma DNA analysis for molecular diagnostics.

Stemmer C, Beau-Faller M, Pencreac'h E, Guerin E, Schneider A, Jaqmin D, Quoix E, Gaub MP, Oudet P

Publication: Clin Chem (2003) • Vol 49 • Page 1953-5PMID: 14578335View on PubMed

Purpose

This paper investigated if the automated Kingfisher DNA extraction kit was comparable to the Qiagen kit in yield of cell-free DNA and investigated the impact of plasma concentration and proteinase K digestion on DNA yield.

Conclusion

The automated Kingfisher kit was comparable to the Qiagen kit in DNA yields from concentrated plasma but resulted in lower yields from non-concentrated plasma. Importantly, the DNA obtained by the automated method was of suitable quality for real-time PCR and microsatellite analysis.

Studies (1)

Purpose

This study investigated if the automated Kingfisher DNA extraction kit was comparable to the Qiagen kit  in yield and quality of cell-free DNA and investigated the impact of plasma concentration and proteinase K digestion on DNA yield. Two EDTA blood specimens were obtained from each of 19 patients with lung cancer, 4 patients with colon cancer, and 20 healthy patients. Plasma was obtained by centrifugation at 800 x g for 10 min and then recentrifuged for 10 min at 1500 x g in a polypropylene tube. Proteins were digested by 1 h incubation with proteinase K at 37˚C in a Tris/SDS/EDTA buffer.  Digests were concentrated and filtered by centrifugation at 2600 x g for 20 min in Amicon Ultra-15 filtration devices. The concentrates were stored at -20˚C until extraction. DNA was extracted using KingFisher silicate magnetic beads and a KingFisher ML robotic magnetic particle processor or using the Qiagen QIAamp DNA Midi reagent.

Summary of Findings

The authors report that protein digestion with proteinase K was necessary to obtain DNA. While DNA yield from the Qiagen kit was not significantly affected by plasma concentration, the yield obtained with KingFisher isolation from concentrated plasma was higher than that obtained with the Qiagen kit from unconcentrated plasma (P=0.009) but was comparable from concentrated plasma (P=0.421). Importantly, the DNA obtained using the automated KingFisher method was of suitable quality for microsatellite amplification, DNA sequencing, and real-time PCR. Although DNA yields were comparable between plasma from cancer patients and healthy controls, the cycle threshold values for GAPDH were higher in specimens from patients than healthy controls.

  • Biospecimens

    CellPlasma
    CellBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    NeoplasticCarcinoma
    Normal
  • Platforms

    DNAFluorometry
    DNAReal-time qPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Cancer
    Healthy
    Biospecimen Aliquots and ComponentsBlood processing method
    Plasma concentrated
    Plasma not concentrated
    Analyte Extraction and PurificationAnalyte isolation method
    KingFisher kit
    Qiagen kit
    Analyte Extraction and PurificationProtein digestion
    No digestion
    Proteinase K
    Real-time qPCR SpecificTargeted nucleic acid
    GAPDH