Skip to main content

Stability of urine specimens stored with and without preservatives at room temperature and on ice prior to urinalysis.

Ercan M, Akbulut ED, Abuşoğlu S, Yılmaz FM, Oğuz EF, Topçuoğlu C, Öztekin V, Boğdaycıoğlu N

Publication: Clin Biochem (2015) • Vol 48 • Page 919-22PMID: 26025772View on PubMed

Purpose

This paper investigated the stability of clinical chemistry and microscopy parameters during storage of urine with or without preservatives on ice for up to 8 h and at room temperature for up to 72 h. 

Conclusion

Greater than 80% agreement with 0 h results was observed for most analytes when urine was stored with or without preservatives for up to 8 h on ice or at room temperature in preservative tubes for 72 h, but lower concordance was observed for WBC clumps and amorphous crystals in specimens stored for 8 h on ice without preservative, WBC counts in specimens stored on ice for 4 or 8 h with preservative, and RBC and WBC counts in specimens stored with preservative at room temperature.

Studies (1)

Purpose

This study investigated the stability of clinical chemistry and microscopy parameters during storage of urine with or without preservatives on ice for up to 8 h and at room temperature for up to 72 h. First-void specimens were collected from 48 patients in an outpatient clinic, but patient diagnosis was not specified. Specimens were divided into BD VacutainerPlus Urinalysis preservative tubes containing chlorohexidine and into polystyrene tubes. Specimens in both tube types were refrigerated and analyzed after 4 and 8 h and specimens in preservative tubes were also stored at room temperature and analyzed after 4, 8, 24, or 72 h. Analysis was performed using iChem VELOCITY Strips on an iChem VELOCITY Urine Chemistry System, iQ200 SPRINT.

Summary of Findings

When urine was stored at room temperature for up to 72 h in preservative tubes, most analytes displayed greater than 80% agreement with results at 0 h, but RBC counts at 72 h were 79.2% concordant with those at 0 h and WBC counts at 24 h and 72 h were only 70.8% and 77.1% concordant, respectively. Interestingly, when specimens were stored in preservative tube on ice packs the WBC counts only displayed 60.4% and 52.1% agreement with the 0 h results after 4 h and 8 h, respectively.  When urine was stored without preservatives on ice packs, agreement with 0 h results for WBC clumps and amorphous crystals was 77.1% and 79.1%, respectively after 8 h of storage, but greater than 80% agreement with 0 h results was found for all other analytes after storage up to 8 h.  Agreement of greater than 80% was achieved for glucose, protein, blood, nitrites, ketones, leukocyte esterase, pH, specific gravity, epithelial cells, casts, bacterial cells yeast, CaOx crystals, and uric acid regardless of storage condition.

  • Biospecimens

    FluidUrine
  • Preservation Types

    Other Preservative
  • Diagnoses

    Not specified
  • Platforms

    CarbohydrateClinical chemistry/auto analyzer
    Cell count/volumeClinical chemistry/auto analyzer
    MorphologyLight microscopy
    Cell count/volumeLight microscopy
    Small moleculeClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Chlorhexadine
    Refrigeration
    StorageStorage duration
    0 h
    4 h
    8 h
    StorageStorage temperature
    On ice
    Room temperature
    StorageTime at room temperature
    0 h
    24 h
    4 h
    72 h
    8 h
    StorageType of storage container
    BD Vacutainer®Plus Urinalysis preservative tubes
    Polystyrene tubes