The effect of centrifugation on three urine protein assays: benzethonium chloride, benzalkonium chloride and pyrogallol red.

Sürer H, Özgün T, Yilmaz FM, Yilmaz G

Publication: Clin Chem Lab Med (2014) • Vol 52 • Page e71-3PMID: 24280287View on PubMed

Purpose

This paper investigated the effects of urine centrifugation, protein level (normal or elevated), and the presence of leukocyte esterase on the measurement of urine protein levels using three different assays as well as creatinine levels.

Conclusion

Protein levels in urine declined with centrifugation, regardless of the analysis method used, but the magnitude of the decline was largest when specimens had protein levels below 140 mg/L and were analyzed using the benzethonium chloride method. Specimens with leukocyte esterase tended to show larger declines than those without, but the difference was not significant. Creatinine levels were unaffected by centrifugation.

Studies (1)

Purpose

This study investigated the effects of urine centrifugation, protein level (normal or elevated), and the presence of leukocyte esterase on the measurement of urine protein levels using three different assays as well as creatinine levels. Protein and creatinine levels were measured in 112 routine urine specimens before and after centrifugation at 1000 x g for 5 min. Protein levels were measured using the pyrogallol red and benzalkonium chloride assays on an Olympus 640 analyzer and using the benzethonium chloride assay on a Modular P analyzer.  Creatinine levels were measured using an Olympus 640 analyzer.  Specimens were divided into those with normal protein levels <140 mg/L (53 specimens) or elevated protein levels >140 mg/L (59 specimens) and based on leukocyte esterase positivity using a dipstick test.

Summary of Findings

Centrifuged urine had significantly lower levels of protein than uncentrifuged urine, regardless of assay (P<0.001 all), but creatinine levels were unaffected by centrifugation. The percentage change in protein levels with centrifugation was dependent on the analysis method used with the largest declines observed using the benzethonium chloride and the smallest using the Pyrogallol red assay.  The percentage change was also dependent on protein level with larger declines noted for specimens with a protein level below 140 mg/L than those above 140 mg/L (P<0.05, all). Although specimens that were positive for leukocyte esterase using dipsticks tended to display larger decreases in protein levels with centrifugation than those negative for leukocyte esterase, the difference was not significant. 

  • Biospecimens

    FluidUrine
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    ProteinClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionBiomarker level
    <140 mg/L protein
    >140 mg/L protein
    Leukocyte esterase absent
    Leukocyte esterase present
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifuged
    Not centrifuged
    Clinical chemistry/auto analyzer SpecificTechnology platform
    Benzalkonium Chloride
    Benzethonium chloride
    Pyrogallol red