Purpose

This paper investigated the effects of amotosalen and ultraviolet A (UVA) treatment on the amplification of four different length amplicons of mitochondrial DNA from platelets (Plts) and plasma and investigated the effects of leukoreduction or plasma concentration through centrifugation.

Conclusion

Cycle threshold (CT) values for mitochondrial DNA increased when white blood cell (WBC) DNA, Plts, or plasma were exposed to amotosalen and UVA illuminated, but a similar increase was not observed when WBC DNA was exposed to amotosalen or UVA illuminated alone. The magnitude of the increase was dependent on the amplicon size with larger increases observed for longer amplicons and when plasma was centrifuged rather than not. The difference in the CT values between the 73 bp and 1065 bp products was able to differentiate treated from untreated Plt or plasma specimens.

Studies (1)

Purpose

This study investigated the effects of amotosalen and UVA treatment on the amplification of four different length amplicons of mitochondrial DNA from Plts and plasma and investigated if there was any effect of leukoreduction or plasma concentration through centrifugation. Six units of individual apheresis Plts were placed in InterSol platelet additive solution (PAS). Leukoreduced and nonleukoreduced Plts were obtained using SEPACALL from eight Plt units obtained by the Plt-rich plasma preparation method. Plasma units were obtained from 10 apheresis units or from whole blood and DNA was extracted directly or after centrifugation at 21,000 x g for 15 min. All Plts and plasma specimens were stored frozen and shipped on dry ice for analysis. Specimens were sampled and treated with amotosalen and then UVA illuminated. The ability of the PCR-based assay to distinguish treated and untreated specimens was checked using 110 Plt units and 100 plasma specimens in a blind study. DNA was extracted using the QIAamp DNA blood kit and mitochondrial DNA was quantified by real-time PCR amplification.

Summary of Findings

Real-time PCR efficiency decreased with increasing amplicon size (100% for 73 bp, 95% for 561 bp, 81% for 1065 bp, and 80% for 1409 bp). The CT of the 73 bp, 1065 bp, and 1409 bp products increased by 7.2, 12.1, and 14.1 cycles (respectively) when Plts in 35% plasma 65% InterSol were treated with amotosalen and then UVA irradiated, but the CTs were comparable to untreated specimens when WBC DNA in 35% plasma 65% PAS was treated with amotosalen or UVA alone. When plasma was treated with amotosalen and UVA irradiated, a similar reduction in the CT of all three products was observed. Interestingly, inclusion of a centrifugation step increased the difference between the CT values of the 73 bp and 1065 bp products, but leukoreduction had no effect. An assay based on the difference in the CT values of the 73 bp and 1065 bp products was able to differentiate treated from untreated specimens using 110 Plt specimens and 100 plasma specimens.

  • Biospecimens

    FluidPlasma
  • Preservation Types

    Frozen
  • Diagnoses

    Not specified
  • Platforms

    DNAReal-time qPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Platelets
    Biospecimen Aliquots and ComponentsBlood processing method
    Leukoreduced
    Non-leukoreduced
    Only UVA treated
    Only amotosalen treated
    UVA and amotosalen treated
    Untreated
    Biospecimen Aliquots and ComponentsCentrifugation
    Different number of centrifugation steps compared
    Real-time qPCR SpecificLength of gene fragment
    1065 bp
    1409 bp
    561 bp
    73 bp