Pre-analytical variables of circulating cell-free nucleosomes containing 5-methylcytosine DNA or histone modification H3K9Me3.

Rasmussen L, Herzog M, Rømer E, Micallef J, Bulut O, Wilhelmsen M, Christensen IJ, Nielsen HJ

Publication: Scand J Clin Lab Invest (2016) • Page 1-10PMID: 27291394View on PubMed

Purpose

This paper investigated the effects of tourniquet usage, time of day of collection, timing of collection relative to colonoscopy/polypectomy or surgery, delayed centrifugation, platelet contamination, inter- and intra-individual variability, and the presence of colorectal cancer on circulating levels of 5-methylcytosine DNA (5mC) and the histone modification H3K9Me3.

Conclusion

Although serum from blood stored at room temperature had 20% higher levels of 5mC and 22% higher levels of H3K9Me3 than serum from blood stored on ice, there were no storage duration dependent effects observed. There was no effect of tourniquet usage, time of collection, or platelet contamination on levels of 5mC and H3K9Me3 in serum or plasma.  Day-to-day inter-individual variation in the levels of 5mC and H3K9Me3 in serum was greater than intra-individual variation. Patients with colorectal cancer had higher levels of 5mC and H3K9Me3 than healthy patients, but there were no differences in levels of 5mC and H3K9Me3 between serum collected prior to or after colonoscopy or colorectal cancer resection.

Studies (4)

Purpose

This study investigated if levels of 5mC and H3K9Me3 in plasma and serum were affected by tourniquet usage or platelet contamination. Blood was collected from 20 healthy fasting patients using a tourniquet for collection from the left arm and no tourniquet for collection from the right. Blood was collected into EDTA and coagulation enhancer tubes. Plasma and serum were obtained by centrifugation at 3000 x g for 10 min. To determine the effects of platelet contamination, the top, middle, and bottom thirds from each tube were carefully transferred to new tubes while leaving 0.5 cm of plasma or serum above the buffy coat. All specimens were frozen at -80˚C. Levels of circulating 5mC and H3K9Me3 were quantified by ELISA.

Summary of Findings

The authors report that levels of 5mC and H3K9Me3 in plasma and serum were not affected by the use of a tourniquet during blood collection. Further, the authors report that levels of 5mC and H3K9Me3 were comparable in the three layers of plasma or serum, indicating no effect of platelet contamination.

  • Biospecimens

    FluidBlood
    FluidPlasma
    FluidSerum
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    DNAELISA
    ProteinELISA
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of fluid acquisition
    Tourniquet times compared
    Biospecimen Aliquots and ComponentsBiospecimen components
    Bottom third
    Middle third
    Top third