Skip to main content

Comparison of 21-gauge and 22-gauge aspiration needle in endobronchial ultrasound-guided transbronchial needle aspiration: results of the American College of Chest Physicians Quality Improvement Registry, Education, and Evaluation Registry.

Yarmus LB, Akulian J, Lechtzin N, Yasin F, Kamdar B, Ernst A, Ost DE, Ray C, Greenhill SR, Jimenez CA, Filner J, Feller-Kopman D

Publication: Chest (2013) • Vol 143 • Page 1036-43PMID: 23632441View on PubMed

Purpose

This paper compared the rate of specimen adequacy and diagnosis of 21-gauge (G) and 22-G endobronchial ultrasound-guided transbronchial needle aspirations (EBUS-TBNA).

Conclusion

EBUS-TBNA obtained with 21-G and 22-G needles had comparable specimen adequacy (94.6% and 94.9%) and diagnosis rates (51.3% and 51.4%, respectively). When ROSE was used, the mean number of needle passes obtained per node was greater in the 22-G group than the 21-G group but the mean number of needle passes was comparable when ROSE was not used.  

Studies (1)

Purpose

This study compared the rate of specimen adequacy and diagnosis of 21- G and 22-G EBUS-TBNA. Data from 1299 patients who underwent EBUS-TBNA at six centers using 21-G (249 patients) or 22-G (995 patients) was analyzed.  Needle gauge and the use of Rapid On-Site Cytological Evaluation (ROSE) were decided by the bronchoscopist. Specimens were defined as adequate if the cytology confirmed the presence of lymphocytes or allowed for diagnosis. The cytologic methods used were not discussed.

Summary of Findings

EBUS-TBNA obtained with 21-G and 22-G needles had comparable specimen adequacy (94.6% and 94.9%) and diagnosis rates (51.3% and 51.4%, respectively). When ROSE was used, the mean number of needle passes obtained per node was greater in the 22-G group than the 21-G group (4.6 versus 3.7, P<0.001) but the number of needle passes was comparable when ROSE was not used (3.2, both).  

  • Biospecimens

    CellLung
    CellLymph Node
  • Preservation Types

    EthanolOther Preservative
  • Diagnoses

    NeoplasticCarcinoma
    NeoplasticBenign
    NeoplasticNot specified
  • Platforms

    MorphologyLight microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionNeedle gauge
    21-G
    22-G