Skip to main content

Fine-needle aspiration biopsy of solid pancreatic masses: comparison of CT and endoscopic sonography guidance.

Erturk SM, Mortelé KJ, Tuncali K, Saltzman JR, Lao R, Silverman SG

Publication: AJR Am J Roentgenol (2006) • Vol 187 • Page 1531-5PMID: 17114547View on PubMed

Purpose

This paper compared diagnostic rate, sensitivity, and negative predictive value (NPV) of computed tomography (CT)-guided and sonography-guided fine needle aspiration (FNA) biopsies of small (≤3 cm) or large (>3 cm) pancreatic lesions.

Conclusion

Compared to sonography-guided biopsies, CT-guided biopsies had non-significantly higher diagnosis rates, sensitivity and NPV; regardless of lesion size. 

Studies (1)

Purpose

This paper compared diagnostic rate, sensitivity, and NPV of CT-guided and sonography-guided FNA biopsies of small (≤3 cm) or large (>3 cm) pancreatic lesions. Forty-three pancreatic lesions were biopsied with a 20-gauge (31 biopsies) or 22-gauge (10 biopsies) needle under CT guidance with (40) or without (3) fluoroscopy in the presence of a cytotechnologist. Twenty-seven pancreatic lesions were biopsied using 22-gauge needles with ultrasound guidance. Cytopathology of all specimens was compared with final diagnosis based on surgical resection specimens or follow-up imaging.

Summary of Findings

Compared to sonography-guided biopsies, CT-guided biopsies had non-significantly higher diagnosis rates (97.7% versus 88.9%), sensitivity (94.9% versus 85%), and NPV (60% versus 57.1%) and these trends were observed regardless of lesion size.  

  • Biospecimens

    CellPancreas
  • Preservation Types

    EthanolOther Preservative
  • Diagnoses

    NeoplasticBenign
    NeoplasticCarcinoma
  • Platforms

    MorphologyLight microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPrognostic factor
    >3 cm lesion
    ≤3 cm lesion
    Biospecimen AcquisitionMethod of cell acquisition
    CT-guided FNA