This paper evaluated the influence of tissue type and processing time, defined as the duration between receipt in the lab until freezing, on the integrity of RNA extracted from frozen specimens The feasibility of obtaining high-quality RNA from vacuum-sealed specimens stored at room temperature was also examined.
RNA quality in fresh-frozen gastrointestinal tumor specimens-experiences from the tumor and healthy tissue bank TU Dresden.
Zeugner S, Mayr T, Zietz C, Aust DE, Baretton GB
Purpose
Conclusion
RNA from tumors isolated from lung or the digestive tract were of significantly poorer quality compared to RNA isolated from breast and kidney tumors but RNA integrity was not affected by specimen processing time. While the authors conclude that RNA isolated from vacuum-sealed pancreas and duodenum tissue is suitable for analysis after 24-96 h at room temperature, RNA quality declined in these specimens after 24 h of storage at room temperature compared to those that were immediately frozen (RIN 4.9 vs 5.5-8.5, respectively). In fact, only 1 of the 11 vacuum-sealed specimens that were subjected to the room temperature timecourse displayed an RIN > 5.
Studies (1)
Purpose
This study investigated the ability to extract high quality RNA from digestive system specimens and the effects of specimen processing time on RNA integrity. RNA was extracted from a total of 171 fresh-frozen tumor specimens from lung, breast, stomach, liver, pancreas, kidney, small intestine, colon, and rectum that were stored at −80 °C or at −135 °C in liquid nitrogen vapor. Processing time, defined as the duration between receipt in the lab until freezing, was recorded for each specimen. To determine feasibility to obtain high-quality RNA from vacuum-sealed specimens stored at room temperature (RT), tumor specimens from duodenum and pancreas were fresh-frozen or vacuum-sealed and stored at room temperature for 24 to 288 hours. RNA was analyzed with a bioanalyzer and RIN values were assigned. Specimens with RIN ≥ 5 were considered to contain high-quality RNA suitable for further studies and specimens with RIN < 5 were determined to contain low quality (degraded) RNA.
Summary of Findings
RIN was influenced by tissue type. Lung specimens had the largest percentage of specimens that yielded poor quality RNA (RIN <5) at 83%, with just 17% of specimens having a RIN ≥ 5. RNA from digestive system specimens was also of poor quality, as demonstrated by the percentage of specimens with an RIN value < 5 for liver (47%), colon (52%), rectum (58%), stomach (74%), pancreas (58%), and small intestine specimens (25%) compared to breast and kidney specimens (27% and 32%, respectively) (P<0.001). While processing times varied as a result of tissue type, no correlation was present between processing time and the percentage of specimens with poor RNA integrity (RIN < 5; P = 0.502). While the authors conclude that RNA isolated from vacuum-sealed pancreas and duodenum tissue is suitable for analysis after 24-96 h at room temperature, RNA quality declined in these specimens after 24 h of storage at room temperature compared to immediately frozen specimens (RIN 4.9 vs 5.5-8.5, respectively). In fact, only 1 of the 11 vacuum-sealed specimens that were subjected to the timecourse displayed an RIN > 5.
Biospecimens
TissueLungTissueBreastTissueLiverTissueStomachTissuePancreasTissueKidneyTissueColorectalTissueSmall BowelPreservation Types
FrozenDiagnoses
NeoplasticCarcinomaPlatforms
ProteinAutomated electrophoresis/BioanalyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Biospecimen location breastcolonkidneyliverlungpancreasrectumsmall intestinestomachBiospecimen Acquisition Cold ischemia time 0 - 50 minutesBiospecimen Preservation Type of fixation/preservation Snap frozenVacuum-sealedStorage Storage duration 0 - 288 h