Assessing quality and functionality of DNA isolated from FFPE tissues through external quality assessment in tissue banks.

Ahmad-Nejad P, Duda A, Sucker A, Werner M, Bronsert P, Stickeler E, Reifenberger G, Malzkorn B, Oberländer M, Habermann JK, Bruch HP, Linnebacher M, Schadendorf D, Neumaier M

Publication: Clin Chem Lab Med (2015) • Vol 53 • Page 1927-34PMID: 26053008View on PubMed

Purpose

This paper examined the effects of formalin-fixed paraffin-embedded (FFPE) section storage and DNA extraction method on DNA yield, purity, maximum amplicon length and the ratio of two PCR fragments.

Conclusion

The maximum PCR fragment length and the ratio of a 379 to 152 bp fragment decreased with FFPE section storage. DNA yield and purity DNA yield, purity, maximum amplicon length and the ratio of 379/152 bp amplicons differed among case-matched FFPE sections extracted at different biobanks, likely due to the different extraction methods employed.

Studies (2)

Purpose

The purpose of this study was to compare DNA yield, purity, maximum amplicon length and amplicon ratio (379/152 bp) among samples extracted from the same FFPE tumor blocks by nine different laboratories. Each of the nine biobanks were sent three nonsequential 10 µM FFPE sections of lung, bile and stomach tumors and three pooled sections of small intestine tumors.  To ensure uniformity between the specimens, serial sections were sent to different biobanks such that one biobank received sections 2, 12, and 22 and another sections 3, 13, and 23. Sections were shipped at ambient temperature, and DNA was extracted at the receiving biobank by their method of choice, and quantified by spectrophotometer before DNA samples were  shipped back to the reference laboratory at room temperature, on ice packs or on dry ice. Upon arrival DNA concentrations and purity were determined by Nanodrop spectrophotometer and protein contamination was quantified using the BCA assay. Specimens were further analyzed by electrophoresis, multiplex PCR, and pyro sequencing of coagulation factor V (379 bp) and calcyphosine (152 bp). All specimens were compared to specimens extracted from the same block at the reference laboratory using the QIAamp DNA FFPE Tissue-Kit and to high molecular weight DNA extracted from buffy coat and degraded by incubation at 95˚C for 2.5-50 min.

Summary of Findings

DNA yield and purity differed among case-matched FFPE  sections extracted at different biobanks, likely due to the different extraction methods employed. While higher or lower yields were consistently obtained from all specimens extracted by some biobanks in comparison to the reference lab, inconsistent results were obtained for others. Similarly, the maximum amplicon size obtained from FFPE specimens was influenced by the biobank that performed the extraction, with consistent amplification of a 411 bp fragment from samples extracted at some biobanks and unsuccessful amplification of a 105 bp fragment from specimens extracted by other biobanks. The ratio of 379/152 bp amplicons was also influenced by the biobank that performed the DNA extractions,  with consistent and higher ratios obtained from specimens processed at some laboratories but not others. Although many extraction details were not described, the authors report that the highest quality DNA was obtained after samples were heated to 95˚C for 10 min during extraction, while  the lowest quality was obtained after samples were heated to 95˚C for 40 min.

  • Biospecimens

    TissueLung
    TissueStomach
    TissueSmall Bowel
    FluidBile
  • Preservation Types

    Formalin
  • Diagnoses

    NeoplasticCarcinoma
    NeoplasticNot specified
  • Platforms

    DNAElectrophoresis
    DNASpectrophotometry
    DNANext generation sequencing
    DNAPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Analyte Extraction and PurificationAnalyte isolation method
    8 unspecified methods
    QIAamp DNA FFPE Tissue-Kit
    PCR SpecificLength of gene fragment
    105 bp
    199 bp
    299 bp
    411 bp
    Next generation sequencing SpecificLength of gene fragment
    152 bp
    379 bp