Skip to main content

Additional Targeted Biopsy in Clinically Suspected Prostate Cancer: Prospective Randomized Comparison between Contrast-Enhanced Ultrasound and Sonoelastography Guidance.

Koh J, Jung DC, Oh YT, Yoo MG, Noh S, Han KH, Rha KH, Choi YD, Hong SJ

Publication: Ultrasound Med Biol (2015) • Vol 41 • Page 2836-41PMID: 26298036View on PubMed

Purpose

This paper investigated the effects of targeting prostate biopsies using either contrast-enhanced ultrasound (CEUS) or sonoelastography (SE) on the diagnosis of prostate cancer.

Conclusion

Targeted biopsy (TB) increased the percentage of cores containing cancer compared to standard biopsy (SB), but did not affect the rate of diagnosis. Significantly more sonoelastography (SE)-guided cores contained cancer than SB cores, but the same was not true for contrast-enhanced ultrasound (CEUS)-guided biopsies. While SB detected cancer at comparable rates in the base, mid-gland, and apex; CEUS and SE biopsies were best at detecting cancers in the mid-gland and apex, respectively. The average Gleason score of the cores was unaffected by targeting method.

Studies (1)

Purpose

This study investigated the effects of targeting prostate biopsies using either CEUS or SE on the diagnosis of prostate cancer.  Fifty-two patients were randomly assigned by computer to have an up to 6 core, 18-gauge biopsy with CEUS (26 patients) or SE (26 patients) guidance.  For each case, an additional 12-core, 18-gauge standard biopsy was obtained by a different pathologist under gray-scale guidance. Preservation is assumed to be standard FFPE. All cores were evaluated by a single pathologist.

Summary of Findings

Comparable diagnostic rates were obtained in matched TB and SB (34.6% versus 40.4%, P=0.3), but a higher percentage of TB cores contained cancer than SB cores (16.4% versus 11.4%, P=0.05). When the results were broken down by method of targeting, significantly more cores obtained with SE guidance contained cancer than SB cores (12.86% versus 4.49%, P=0.01), but the number of cancer-containing cores obtained by CEUS-guided biopsy and SB was comparable (18.8% versus 18.3%). Although cancer detection rates in SB were comparable to rates in TB in the base, mid-gland, and apex; SE was best at detecting cancer in the apex (8 of 9, 89%) and CEUS was best at detecting cancer in the mid-gland (16 of 19, 84%). Gleason scores were similar in CEUS and SE biopsies. 

  • Biospecimens

    TissueProstate
  • Preservation Types

    Formalin
  • Diagnoses

    NeoplasticBenign
    NeoplasticCarcinoma
  • Platforms

    MorphologyLight microscopy
    MorphologyH-and-E microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of tissue acquisition
    Multiple targeting methods compared
    Ultrasound-guided biopsy