This paper compared serum levels of cortisol, triiodothyronine (TT3), total thyroxine (TT4), and fourteen clinical chemistry analytes among specimens collected in seven different kinds of blood collection tubes.
Performance of chemically modified plastic blood collection tubes.
Bowen RA, Kim SC, Sattayapiwat A, Austria-Esguerra V, Zare RN
Purpose
Conclusion
Compared to serum collected in glass tubes, serum collected in rapid serum tubes (RST) had significantly higher cortisol and TT4 levels and serum collected in serum separator tubes (SST) had higher cortisol levels but the authors state that these differences were not clinically relevant. No other statistically or clinically significant differences were noted but bias between tubes did exceed the quality control recommendations for some analytes. Further, no significant effects were observed on serum analytes when blood was collected in the chemically-modified polyethylene terephthalate tubes (PET) rather than glass tubes even after storage for 20 months.
Studies (1)
Purpose
This study compared serum levels of cortisol, triiodothyronine (TT3), total thyroxine (TT4), and fourteen clinical chemistry analytes among specimens collected in seven different kinds of blood collection tubes. Blood was collected from 60 healthy, seated volunteers using standard techniques. All specimens were obtained from the same venipuncture with the exception of the chemically-modified PET tubewhich was first collected in a plastic syringe and then dripped into the tube that was first incubated with 1,1,3,3-tetramethylguanidine (TMG) solution in ethylene glycol (EG) and then rinsed in deionized water. All tubes were inverted 8-10 times, walked 50 feet, and left upright for 60 min before centrifugation. After centrifugation, sera from tubes not containing gel was transferred to a new tube. All sera was frozen at -80˚C and analyzed within 3 days.
Summary of Findings
Compared to serum collected in glass tubes, serum collected in RST had significantly higher cortisol (P<0.0001) and TT4 (P=0.011) and serum collected in SST had higher cortisol levels (P=0.0005), but the authors state that these differences were not clinically relevant. Importantly, the range of the bias for each tube compared to glass was only -1.3% - 1.54% for cortisol, -1.44 - 2.88% for TT3 and -0.22 - 1.54% for TT4. Blood collection tube type did not significantly or clinically affect TT3, sodium, potassium, chloride, carbon dioxide, glucose, urea nitrogen, creatinine, calcium, albumin, total protein, total bilirubin, aspartate aminotransferase (AST), alanine aminotransferase (ALT), or alkaline phosphatase (ALP) levels in serum; but the bias in albumin, aspartate aminotransferase, blood urea nitrogen, total calcium, chloride, glucose, potassium, sodium, and total bilirubin ranged from -9.9% - 16.7% ,which exceeds the quality control recommendations. Regardless of collection tube type, all specimens had serum hemolysis, icterus, and lipemia index scores of 1. Further, no significant effects were observed on serum analytes when blood was collected in the chemically-modified PET rather than glass tubes even after storage for 20 months before use.
Biospecimens
FluidBloodFluidSerumPreservation Types
FrozenDiagnoses
NormalPlatforms
CarbohydrateClinical chemistry/auto analyzerElectrolyte/MetalClinical chemistry/auto analyzerGasClinical chemistry/auto analyzerPeptideClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerSteroidClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerCell count/volumeSpectrophotometryLipidSpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution Chemically modified tubes made from unmodified PET Vacutainer tubes with no interior coatingGlass tubePlastic RST tube with gelPlastic SST tube with gelPlastic VacuettePlastic discard Vacutainer tube without gelPlastic plain red-top Vacutainer tube without gel separator