This paper compared the diagnostic accuracy and detection of necrosis and calcification between core needle biopsy (CNB) and vacuum-assisted biopsy (VAB) breast specimens and determined the effect of number of CNB cores sampled on diagnostic accuracy.
Biopsy sampling of breast lesions: comparison of core needle- and vacuum-assisted breast biopsies.
Lacambra MD, Lam CC, Mendoza P, Chan SK, Yu AM, Tsang JY, Tan PH, Tse GM
Purpose
Conclusion
The diagnostic positive predictive value (PPV), negative predictive value (NPV), sensitivity, and specificity were higher for VAB than CNB. For CNB specimens, the average number of cores was higher in cases in which the correct diagnosis was obtained than in those that it was not and diagnostic accuracy increased from 96% to 97% when at least 3–4 cores were collected. Larger calcifications were associated with malignancy both in VAB and CNB specimens but lesion mass was only significantly associated with malignancy in specimens sampled by CNB.
Studies (1)
Purpose
This study compared the diagnostic accuracy and detection of necrosis and calcification of CNB and VAB of breast lesions and determined the effect of the number of CNB cores obtained on diagnostic accuracy. This study was a retrospective analysis of breast lesions that were sampled by VAB (179 lesions) or CNB (285 lesions) with subsequent diagnosis based on surgical resection over a two-year period. Although generally the decision of VAB versus CNB was random, VAB was selected in cases where the entire lesion could be removed by VAB resulting in a smaller average lesion size (2.1 cm versus 1.4 cm). All specimens were fixed in formalin and H&E stained.
Summary of Findings
Per patient, an average of 7.04 cores (range of 1-30) were obtained by VAB and 4.35 by CNB (1-13 cores). The diagnostic PPV, NPV, sensitivity, and specificity were 98%, 94%, 96%, and 99% respectively for CNB and 100% for all parameters for VAB. For CNB specimens, the average number of cores for cases in which the correct diagnosis was achieved was 4.39 and the average number for cases in which an incorrect diagnosis was achieved was 3.4 (P=0.04). Further, when at least 3-4 cores were obtained by CNB, the diagnostic accuracy increased from 96% to 97%. Larger calcifications were associated with malignancy both in VAB (r=0.52, P<0.05) and CNB (r=0.22, P<0.01) specimens, but lesion mass was only significantly associated with malignancy in specimens sampled by CNB (P<0.01). Necrosis and calcification were detected at similar rates in palpable lesions by CNB and VAB, but in non-palpable lesions VAB was better at detecting calcification (P<0.01).
Biospecimens
TissueBreastPreservation Types
FormalinDiagnoses
NeoplasticBenignNeoplasticCarcinomaPlatforms
MorphologyH-and-E microscopyPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Prognostic factor CalcifiedNecrosisNo necrosisNon-calcifiedNon-palpable massPalpable massBiospecimen Acquisition Method of tissue acquisition Core needle biopsySurgical resectionVacuum assisted biopsyBiospecimen Aliquots and Components Biospecimen heterogeneity Intratumoral sampling (exact positions not specified)