EUS-guided 22-gauge fine-needle aspiration versus core biopsy needle in the evaluation of solid pancreatic neoplasms.

Strand DS, Jeffus SK, Sauer BG, Wang AY, Stelow EB, Shami VM

Publication: Diagn Cytopathol (2014) • Vol 42 • Page 751-8PMID: 24550162View on PubMed

Purpose

The purpose of this paper was to compare the technical performance and diagnostic capability of endoscopic ultrasound-guided (EUS) fine-needle aspiration (FNA) or fine-needle biopsy (FNB) of pancreatic lesions.

Conclusion

The ability to achieve a diagnosis was significantly lower in FNB specimens compared to FNA specimens (28.1 vs 93.8%; p<0.001); however, FNA specimens contained more contaminants than FNB specimens (0.813 vs 0.421; p=0.036), although the source of contamination was not specified by the authors.  Differences in mean cellularity between FNB and FNA specimens were not significant (1.632 vs 2.095, respectively).

Studies (1)

Purpose

The purpose of this paper was to compare the technical performance and diagnostic capability of endoscopic ultrasound-guided (EUS) fine-needle aspiration (FNA) and fine-needle biopsy (FNB) specimens from solid pancreatic masses. Specimens from a solid pancreatic mass were collected from 32 patients by both FNA and FNB using endoscopic ultrasound guidance.  Both FNA and FNB specimens were collected using a 22 gauge needle, although a mean of 1.4 passes were performed for FNB while a mean of 2.9 passes were performed for FNA. FNA specimens were alcohol-fixed and Papanicolaou stained, while FNB specimens were formalin-fixed and hematoxylin and eosin-stained. 

Summary of Findings

FNB specimens were only obtained from 27 patients (84.4%, due to resistance preventing needle deployment), but FNA were available from all 32 patients.  While sufficient material was obtained from all 32 FNA specimens, only 18 FNB specimens yielded sufficient material (56.2%).. The ability to achieve a diagnosis was significantly lower in FNB specimens compared to FNA specimens (28.1 vs 93.8%; p<0.001); however, FNA specimens contained more contaminants that FNB specimens (0.813 vs 0.421; p=0.036), although the authors failed to specify the source of contamination.  Differences in mean cellularity between FNB and FNA specimens were not significant (1.632 vs 2.095, respectively).

  • Biospecimens

    TissuePancreas
  • Preservation Types

    EthanolFormalin
  • Diagnoses

    NeoplasticCarcinoma
  • Platforms

    MorphologyH-and-E microscopy
    MorphologyLight microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of tissue acquisition
    Biopsy
    Fine needle aspiration
    Light microscopy SpecificType of tissue stain
    Pananocolaou stain