The purpose of this paper was to compare diagnostic accuracy, sensitivity and specificity between ultrasound-guided core needle biopsy (US-CNB) and endoscopic ultrasound-guided fine-needle aspirations (EUS-FNA) of solid pancreatic lesions.
Comparison of Ultrasound-Guided Core Needle Biopsy and Endoscopic Ultrasound-Guided Fine-Needle Aspiration for Solid Pancreatic Lesions.
Sur YK, Kim YC, Kim JK, Lee JH, Yoo BM, Kim YB
Purpose
Conclusion
The proportion of specimens with an accurate diagnosis was higher for US-CNB than EUS-FNA specimens when those that failed due to technical issues were included (86.11% versus 65.71%). However, the diagnostic accuracy (for successful specimens), sensitivity and specificity were higher, albeit not significantly, for specimens procured by US-CNB compared to EUS-FNA specimens.
Studies (1)
Purpose
The purpose of this study was to compare diagnostic accuracy, sensitivity and specificity between US-CNB and EU-FNA specimens of solid pancreatic lesions. A total of 63 EUS-guided FNA specimens procured with a 25-gauge needle, and 35 US-guided CNB specimens procured with an 18-gauge needle were obtained from 89 patients with solid pancreatic lesions identified by CT or magnetic resonance imaging (MRI). Biopsy method was determined by the clinician, but clinicians favored EUS-FNA when possible based on location unless the lesion was suspect for pancreatitis. The 35 US-CNB specimens included 10 cases in which the initial diagnosis by EUS-FNA was presumed inaccurate. Malignant lesions were confirmed after surgical resection. Benign pancreatic lesions were confirmed by US-CNB or by clinical or imaging follow-up after 1 year.
Summary of Findings
Overall the diagnostic accuracy of US-guided CNB was 88.57% (31 of 35 cases), which did not differ significantly from EUS-guided FNA (73.02%, 46 of 63 cases). However, when specimens that failed due to technical issues were included the proportion of specimens with an accurate diagnosis was significantly higher for US-CNB than EUS-FNA (86.11% versus 65.71%, p=0.035). US-CNB rather than EUS-FNA was more likely to correctly diagnose malignant (sensitivity of 87.10% versus 77.78%) and benign lesions (specificity of 100% versus 44.44%), but the differences were not significant, regardless of lesion size or location within the pancreas. Generally, diagnostic accuracy and diagnosis rate increased with increasing the lesion size.
Biospecimens
TissuePancreasPreservation Types
FormalinDiagnoses
NormalOther diagnosesNeoplasticCarcinomaNeoplasticBenignPlatforms
MorphologyLight microscopyPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Prognostic factor 2-4 cm lesion<2 cm lesion>4 cm lesionBiospecimen Acquisition Biospecimen location Pancreatic body and neckPancreatic head and uncinateBiospecimen Acquisition Method of tissue acquisition Core needle biopsyFine needle aspirationUltrasound-guided biopsyUltrasound-guided fine needle aspiration