Skip to main content

Comparison of cell stabilizing blood collection tubes for circulating plasma tumor DNA.

Toro PV, Erlanger B, Beaver JA, Cochran RL, VanDenBerg DA, Yakim E, Cravero K, Chu D, Zabransky DJ, Wong HY, Croessmann S, Parsons H, Hurley PJ, Lauring J, Park BH

Publication: Clin Biochem (2015) • Vol 48 • Page 993-8PMID: 26234639View on PubMed

Purpose

The purpose of this paper was to compare cell-free DNA levels in plasma among blood specimens collected in different tube types and subjected to a pre-processing delay of 7 days at room temperature.

Conclusion

Generally, the number of copies of cell-free DNA in plasma were higher when blood was stored for 7 days at room temperature in EDTA or PAXgene tubes, but remained comparable to immediately processed specimens when blood was stored in Streck blood collection tubes (BCT). However, one of the phosphatidylinositol-4,5-bisphosphate 3-kinase, catalytic subunit alpha (PIK3CA) hotspot mutations as well as fetal DNA levels were not affected by the pre-processing delay, regardless of tube type. 

Studies (2)

Purpose

The purpose of this study was to compare the stabilities of fetal and total cell-free DNA in plasma collected from pregnant women. Blood from a pregnant volunteer was collected into EDTA and BCT tubes and was processed by double centrifugation within 2 h or after 7 days at room temperature. Additional blood from another pregnant volunteer was collected into EDTA, BCT and PAXgene tubes. EDTA specimens were processed by double centrifugation within 2 h while PAXgene and BCT specimens were processed after 7 days at room temperature. Cell-free DNA was extracted from the plasma specimens using the QIAamp Circulating Nucleic Acid kit. Fetal DNA was quantified by digital PCR amplification of E1F1AY region of the Y chromosome and total DNA was quantified by amplification of wild-type PIK3CA exon 9.

Summary of Findings

Compared to controls processed within 2 h, the number of copies of total cell-free DNA in plasma was unaffected by a pre-processing delay of 7 days at room temperature when specimens were collected and stored in BCT tubes, but the number of copies increased by >10- and >5-fold when blood was collected and stored in EDTA or PAXgene tubes, respectively. Plasma levels of fetal cell-free DNA were not affected by a pre-processing delay of 7 days at room temperature for any of the tube types examined (EDTA, BCT or PAXgene tubes).

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    PAXgeneStreck/BCTNone (Fresh)
  • Diagnoses

    Pregnant
  • Platforms

    DNADigital PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    BCT tube
    EDTA tube
    PAXgene tube
    Biospecimen PreservationType of fixation/preservation
    Blood collection tube additive
    None (fresh)
    PAXgene
    StorageTime at room temperature
    7 days
    <2 h
    Digital PCR SpecificTargeted nucleic acid
    E1F1AY
    PIK3CA exon 9