Skip to main content

Influence of storage conditions and extraction methods on the quantity and quality of circulating cell-free DNA (ccfDNA): the SPIDIA-DNAplas External Quality Assessment experience.

Malentacchi F, Pizzamiglio S, Verderio P, Pazzagli M, Orlando C, Ciniselli CM, Günther K, Gelmini S

Publication: Clin Chem Lab Med (2015)PMID: 25883202View on PubMed

Purpose

The purpose of this paper was to determine the effects of DNA extraction method and delayed isolation on the yield of cell-free DNA. Inter-laboratory variability was also examined.

Conclusion

The integrity of cell-free DNA was variable among the 56 participating laboratories. While no effect of storing plasma beyond the recommended 3 days at 4ºC was identified, use of a cell-free DNA-specific DNA extraction kit rather than a general DNA extraction kit resulted in more intact DNA when extraction was performed within 3 days.

Studies (1)

Purpose

The purpose of this study was to determine the effect of DNA extraction method and delayed isolation on the yield of cell-free DNA. Inter-laboratory variability was also examined. Plasma from a single healthy donor was obtained by double centrifugation, aliquoted, stored at 4ºC and shipped at 2-8ºC. After arrival, specimens were stored for <3 days at 4ºC before DNA extraction. Extracted DNA was then shipped back at 4ºC. DNA integrity was determined by the multiplex PCR-based DNA Quality Check Kit. Importantly, the analysis of plasma storage and extraction kit only included the 50 laboratories that reported the plasma having arrived at the appropriate temperature and in the appropriate condition.

 

Summary of Findings

Of the 56 participating laboratories, 4 (7%) failed to isolate amplifiable cell-free DNA, 20 (36%) isolated DNA of low integrity (100-200 bp maximum length), 25 (44.6%) isolated DNA of intermediate integrity and 7 (12.5%) isolated high integrity DNA (600 bp maximum length). There was no significant difference in RNA integrity among specimens processed at the 44 laboratories that stored plasma for <3 days at 4ºC and the 6 that stored plasma at -80ºC or 4ºC for up to 12 days. When extraction was performed within 3 days of blood collection, kits tailored to cell-free DNA generated more intact DNA than general DNA extractions kits; however, no such difference among extraction kits were observed when all delays and laboratories were compared.

  • Biospecimens

    FluidPlasma
  • Preservation Types

    Other Preservative
  • Diagnoses

    Normal
  • Platforms

    DNAPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageStorage duration
    3-12 days
    <3 days
    StorageStorage temperature
    -80ºC or 4ºC
    4ºC
    Analyte Extraction and PurificationAnalyte isolation method
    Cell-free DNA extraction kit
    General DNA extraction kit
    PCR SpecificLength of gene fragment
    100 bp
    200 bp
    300 bp
    400 bp
    500 bp
    600 bp