Skip to main content

The effect of pre-analytical variability on the measurement of MRM-MS-based mid- to high-abundance plasma protein biomarkers and a panel of cytokines.

Aguilar-Mahecha A, Kuzyk MA, Domanski D, Borchers CH, Basik M

Publication: PLoS One (2012) • Vol 7 • Page e38290PMID: 22701622View on PubMed

Purpose

This paper investigated whether a room temperature processing delay, and use of protease inhibitors (P100 tubes) or tube additives that prevent platelet activation (CTAD tubes), affect the levels of 56 medium to high abundance plasma proteins and 20 cytokines.  Potential effects of centrifugation protocols on cytokine levels were also explored.

Conclusion

Peptide and cytokine levels were affected by the type of tube used for blood collection.  Plasma from CTAD tubes displayed lower peptide levels in immediately processed specimens, and more stable levels in those subjected to a processing delay than plasma from either EDTA or P100 tubes.  In fact, peptide levels were not significantly affected by a room temperature processing delay of up to 6 h when blood was collected in CTAD tubes, while plasma collected in other tube types exhibited significant changes over time.  While 20 of the 27 cytokines targeted by the immunoassay were detectable in plasma collected in EDTA or P100 tubes, only 11 cytokines were detectable in plasma from CTAD tubes, which suggests elevated levels were due to platelet activation. Plasma from P100 tubes (the only tube investigated) displayed altered levels of up to 80% of the cytokines analyzed when centrifugation conditions were compared, specifically levels were elevated when specimens underwent centrifugation at 8°C compared to those centrifuged at room temperature. 

Studies (2)

Purpose

This study investigated whether a room temperature processing delay and the use of protease inhibitors or tube additives that prevent platelet activation affect the detection or levels of 56 medium to high abundance plasma proteins.  Blood was collected from 14 healthy but fasting individuals into K2EDTA tubes, BD P100 tubes (K2EDTA and a protease inhibitor cocktail), and CTAD tubes (citrate and additives that prevent platelet activation) and processed after a 0, 2, or 6 h room temperature delay.  Specimens were processed similarly, and plasma was stored at -80°C prior to analysis. 

Summary of Findings

A processing delay of 2-6 h did not significantly alter plasma peptide levels when blood was collected in CTAD or EDTA tubes without a protease inhibitor. However, when blood was collected in P100 tubes 7 of the 56 peptides analyzed declined significantly after a 2 h delay (p<0.05), and 5 declined significantly after a 6 h delay (p<0.05) compared to immediately processed specimens. Differences between EDTA plasma collected with and without protease inhibitors over processing delays of up to 6 h were limited to a single peptide, as levels of plasminogen were significantly, but modestly higher (by 4%) in plasma collected in EDTA tubes compared to P100 tubes. Conversely, plasma collected in CTAD tubes displayed lower peptide levels than plasma collected in other tube types both in immediately processed specimens and those subjected to a processing delay, suggesting that release of these peptides may be influenced by platelet activation. Of the 56 peptides analyzed, 21, 28 and 41 peptides displayed 10-48% lower levels in plasma collected in CTAD tubes compared to plasma collected in one or both of the other tube types (K2EDTA and/or P100 tubes) after a 0 h, 2 h and 6 h processing delay, respectively. Fibronection was the only peptide with higher levels in CTAD tubes over the 6 h time course (64-128%) compared to EDTA tubes with and without a protease inhibitor.

  • Biospecimens

    FluidPlasma
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    PeptideMRM-MS
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    BD P100 tube
    CTAD tube
    K2EDTA tube
    StorageTime at room temperature
    0 h
    2 h
    6 h
    Analyte Extraction and PurificationProtease inhibitor
    Cocktail
    No protease inhibitor added