Skip to main content

Time-Dependent and Sample-to-Sample Variations in Human Plasma Peptidome are Both Minimized Through Use of Protease Inhibitors

Craft D, Yi Jizu, Gelfand CA

Publication: Analytical Letters (2009) • Vol 42 • Page 1398-1406

Purpose

The purpose of this paper was to compare the plasma peptidome  between EDTA blood collected into tubes with and without protease inhibitors both when blood was processed immediately and after a processing delay.

Conclusion

While plasma peptide content was greater when blood was collected into EDTA tubes that lacked protease inhibitors, EDTA plasma from collection tubes that contained a protease inhibitor cocktail displayed more uniform peptide spectra between individuals and more stable peptide content after a 4 hour processing delay. 

Studies (2)

Purpose

The purpose of this study was to determine whether blood collected into tubes containing protease inhibitors display an altered EDTA plasma peptidome and to determine the effect of protease inhibitors on between-patient  variability. Blood was collected from three healthy individuals into two tubes: EDTA tubes, P100 tubes (contains EDTA and a protease inhibitor cocktail).  Blood was left in the original collection tube at room temperature for 0, 60, 120, 180, or 240 min prior to plasma processing by centrifugation and filtration. Peptide spectra were visualized after fractionation on a nano-HPLC system.

Summary of Findings

Blood collected in tubes containing a protease inhibitor cocktail (P100 tubes), displayed more uniform peptide spectra following room temperature storage compared to those collected into EDTA tubes. Variability among peptide spectra between patients was also reduced among specimens collected in P100 tubes in comparison to EDTA tubes.  

  • Biospecimens

    FluidPlasma
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    PeptideHPLC
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    BD P100 (EDTA and Protease inhibitor cocktail)
    BD Vacutainer PPT (EDTA)
    StorageTime at room temperature
    0 min
    120 min
    180 min
    240 min
    60 min
    Analyte Extraction and PurificationProtease inhibitor
    Cocktail
    No protease inhibitor added