Peptidomic analysis of human blood specimens: comparison between plasma specimens and serum by differential peptide display.

Tammen H, Schulte I, Hess R, Menzel C, Kellmann M, Mohring T, Schulz-Knappe P

Publication: Proteomics (2005) • Vol 5 • Page 3414-22PMID: 16038021View on PubMed

Purpose

The purpose of this paper was to compare and contrast mass spectrometry-generated peptide profiles among serum, EDTA plasma, citrate plasma, and heparin plasma. The potential impact of centrifugation temperature during plasma processing on peptide profiles was also investigated.  

Conclusion

Serum had a greater number of peptides compared to either EDTA or citrate plasma.  In fact, more than 40% of peptides identified in serum were determined to be serum-specific, many of which were involved in clotting.  The authors conclude that platelet poor plasma (PPP) generated by ultrafiltration or two rounds of centrifugation at room temperature is optimal for peptide profiling by mass spectrometry.  Centrifugation at a lower temperature (4°C) was associated with platelet activation and subsequent contamination with platelet-related peptides.  EDTA and citrate anticoagulants yielded similar peptide profiles, but heparin plasma expanded the fractionation range, altering a peptide's elution position.

Studies (2)

Purpose

The purpose of this study was to compare and contrast mass spectrometry-generated peptide profiles among serum, EDTA plasma, citrate plasma, and heparin plasma. A total of 22 samples were collected from healthy males into tubes containing clot activator (serum) or EDTA, heparin, or citrate (plasma).  Prior to freezing at -80C, plasma specimens were centrifuged and filtered (0.2 m pore size).  After a clot time of 1 h, serum was centrifuged and frozen at -80°C. Specimens were fractionated by reversed-phase (RP)-HPLC prior to peptide identification by matrix-assisted laser desorption/ionization tandem mass spectrometry (MALDI-TOF MS/MS) and electrospray ionization quadrupole time-of-flight tandem mass spectrometry (nESI-qTOF MS/MS).  

Summary of Findings

While plasma generated with EDTA and citrate displayed similar peptide profiles, plasma generated with heparin displayed a broader fractionation range. The authors postulate that the altered elution range and position for certain peptides is a result of chromatographic interference.  Serum had a greater number of peptides compared to either EDTA or citrate plasma.  In fact, more than 40% of peptides identified in serum were determined to be serum-specific, many of which were involved in clotting. 

  • Biospecimens

    FluidPlasma
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    PeptideHPLC
    PeptideMALDI-TOF MS
    PeptideESI-TOF-MS
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnticoagulant
    Citrate
    EDTA
    Heparin
    None
    Biospecimen AcquisitionBiospecimen location
    Plasma
    Serum