Functional DNA quantification guides accurate next-generation sequencing mutation detection in formalin-fixed, paraffin-embedded tumor biopsies.

Sah S, Chen L, Houghton J, Kemppainen J, Marko AC, Zeigler R, Latham GJ

Publication: Genome Med (2013) • Vol 5 • Page 77PMID: 24001039View on PubMed

Purpose

The purpose of this paper was to compare different methods of DNA quantification and optimize the real-time PCR based quantitative functional index (QFI) to allow for reliable identification of mutations in FFPE tissues using targeted next-generation sequencing (NGS).

Conclusion

The quantified yield of DNA was 17-fold higher by NanoDrop than by Qubit. The authors report that using QFI score to adjust the nanogram amount of DNA for NGS analysis can ensure sufficient amplifiable template, and screening specimens using a QFI threshold of >6% can reduced the incidence of false negatives and false positives.

Studies (2)

Purpose

The purpose of this study was to compare quantification methods for DNA extracted from FFPE specimens. A total of 165 FFPE specimens that were commercially obtained and stored for 1-18 years prior to analysis were used. FFPE specimens included 10 biopsy specimens each from ovary, colon, skin, breast and lung purchased from the Asuragen FFPE database, 76 FFPE thyroid biopsies purchased from Asterand, and 39 colorectal tumor resections purchased from Folio. DNA was extracted from all specimens using the RecoverAll FFPE kit. Each DNA sample was quantified using a spectrophotometer (Nanodrop), a DNA-binding fluorescent dye (Qubit), and a qPCR-based assay (QFI) that corresponds to the percentage of functional template for a given target.

Summary of Findings

DNA amounts varied greatly among quantification methods, as the same specimen set resulted in a mean DNA yield of 5 ng with Nanodrop and 0.30 ng with Qubit, a 17-fold difference. Differences in the percentage of samples below the threshold of detection also differed between Qubit and QFI, as 19.4 and 6.1% of specimens failed to generate data, respectively. For specimens with a QFI score >3% there was a modest linear correlation between relative DNA concentration determined by Qubit and QFI score (R=0.66), while no correlation was observed for specimens with lower QFI scores.  

  • Biospecimens

    TissueBreast
    TissueOvary
    TissueColorectal
    TissueSkin
    TissueLung
    TissueThyroid Gland
  • Preservation Types

    Formalin
  • Diagnoses

    NeoplasticNot specified
    NeoplasticCarcinoma
  • Platforms

    DNASpectrophotometry
    DNAFluorometry
    DNAReal-time qPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Spectrophotometry SpecificQuality metrics
    Determined by QFI
    Determined by Qubit
    Spectrophotometry SpecificTechnology platform
    NanoDrop
    Qubit
    Real-time PCR