Skip to main content

microRNA biomarker discovery and high-throughput DNA sequencing are possible using long-term archived serum samples.

Rounge TB, Lauritzen M, Langseth H, Enerly E, Lyle R, Gislefoss RE

Publication: Cancer Epidemiol Biomarkers Prev (2015) • Vol 24 • Page 1381-7PMID: 26108462View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage duration, freezing, lyophilization, the additive iodacetate, and clotting time on miRNA and DNA yields and the percentage of miRNA (10-40 nt) of total small RNA (0-150 nt) in serum.

Conclusion

The average miRNA yield was higher from lyophilized serum than from serum stored at -20°C. Increasing frozen storage may have decreased the percentage of miRNA and increased DNA yield in the health examinations (HE) cohort, but the effects were complicated by the use of the additive iodacetate in the oldest specimens. Importantly, similar effects were not reproduced in a separate specimen cohort of Red Cross blood donors (RCBD) in which the oldest specimens did not contain the additive. The additive iodacetate may have attenuated the effects of frozen storage on DNA yields and miRNA percentages, but did not improve miRNA yields. Differences in DNA yield and miRNA percentage were present between the two specimen cohorts that were attributed to differences in clot time (1 h versus 14-28 h), but differences in storage duration and use of the tube additive iodacetate were confounding variables.

Studies (2)

Purpose

The purpose of this study was to compare miRNA yield from fresh serum, frozen lyophilized serum, and serum frozen with or without the additive iodacetate. Serum specimens were subjected to different storage durations and clotting times. Serum specimens that were collected during a health examination (HE) included 44 specimens collected with the additive iodoacetate (1972-1978), 44 specimens collected with no additives (1979-1986), and 49 specimens collected in gel tubes (1987-2004). HE specimens were centrifuged within 1 h, shipped cold and frozen at -20°C. Serum specimens collected from Red Cross blood donors (RCBD) included 4 specimens collected without additive between 1973-1979, 42 lyophilized specimens collected between 1973-1979, 48 specimens collected without additive between 1980-1990 and 45 specimens collected without additive between 1997-2004. All RCBD specimens were stored overnight (14-28 h clotting time), processed to serum and frozen at -20°C or lyophilized. HE and RBCD specimens had been thawed 1-3 times previously, but potential effects were not explored. Additionally, 43 fresh serum specimens isolated following  a 1 h clotting time were included. RNA was extracted using TRIzol LS with the miRNeasy Serum/Plasma Kit. Storage durations were calculated based on specimens collected in 1972 having been stored for 40 years.

Summary of Findings

Average miRNA yields were higher from lyophilized serum than serum stored at -20°C (p≤0.05), and from fresh serum than frozen serum collected with the additive iodacetate stored for 34-40 years (p=0.023). The percentage of miRNA (10-40 nt) in relation to amount of total small RNA (0-150 nt) was greater in HE specimens collected with the additive iodacetate and stored 34-40 years than in HE specimens that did not contain the additive and were stored 8-25 years (p=0.042) or 26-33 years (p<0.001), indicating a potential effect of storage duration or a protective effect of the additive iodacetate. However, as RCBD specimens, which had similar storage durations (8-15, 22-32 and 33-39 years) but did not contain the additive and had longer clotting time compared to HE specimens (14-28 h versus 1 h) displayed no differences in the percentage of miRNA in relation to small RNA, the effect is more likely attributable to the additive.

  • Biospecimens

    FluidSerum
    FluidBlood
  • Preservation Types

    FrozenNone (Fresh)Other Preservative
  • Diagnoses

    Normal
  • Platforms

    RNAAutomated electrophoresis/Bioanalyzer
    RNANext generation sequencing
    RNAReal-time qRT-PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    Gel tube
    Plain tube
    Tube containing iodacetate
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    Biospecimen PreservationType of fixation/preservation
    Frozen
    Lyophilized
    None (fresh)
    StorageStorage duration
    0 years
    1 h
    14-28 h
    16-33 years
    26-32 years
    33-39 years
    34-40 years
    8-15 years
    8-25 years