High sensitivity C-reactive protein (Hs-CRP) remains highly stable in long-term archived human serum.
Doumatey AP, Zhou J, Adeyemo A, Rotimi C
Purpose
The purpose of this paper was to determine the effects of long term storage of serum on levels of C Reactive Protein (CRP).
Conclusion
CRP levels were not significantly different after storage of serum for 7-11 years at -80 degrees C than when assayed within the recommended storage time-frame (<8 days at 4 degrees C or <3 years at -20 degrees C).
Studies (1)
Purpose
The purpose of this study was to determine the effects of long term storage of serum on levels of CRP. Initial analysis of CRP levels in 30 serum specimens from healthy individuals was conducted on the day of collection or following the manufacturers recommendation of after <8 days at 4 degrees C or <3 years at -20 degrees C (average 3 months). Following baseline measurement, all specimens were stored at -80 degrees C and thawed 7-11 years later, at which point they were assayed by the same method, but using newer reagents.
Summary of Findings
CRP levels were nonsignificantly higher in specimens stored for 7-11 years (average 8.7 years) at -80 degrees C than when initially assayed (after 0 days, <8 days at 4 degrees C, or <3 years at -20 degrees C). This continued to be true when specimens were separated by timing of initial assay (0-8 days, 9-80 day, or 80 days-3 years).
Biospecimens
FluidSerumPreservation Types
FrozenDiagnoses
NormalPlatforms
ProteinClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage duration 0 days to <3 years0-8 days7-11 years80 days to 3 years9-80 days